Class: Tinkerforge::BrickletHumidity

Inherits:
Device
  • Object
show all
Defined in:
lib/tinkerforge/bricklet_humidity.rb

Overview

Measures relative humidity

Constant Summary collapse

DEVICE_IDENTIFIER =

:nodoc:

27
DEVICE_DISPLAY_NAME =

:nodoc:

'Humidity Bricklet'
CALLBACK_HUMIDITY =

This callback is triggered periodically with the period that is set by BrickletHumidity#set_humidity_callback_period. The parameter is the humidity of the sensor.

The CALLBACK_HUMIDITY callback is only triggered if the humidity has changed since the last triggering.

13
CALLBACK_ANALOG_VALUE =

This callback is triggered periodically with the period that is set by BrickletHumidity#set_analog_value_callback_period. The parameter is the analog value of the sensor.

The CALLBACK_ANALOG_VALUE callback is only triggered if the humidity has changed since the last triggering.

14
CALLBACK_HUMIDITY_REACHED =

This callback is triggered when the threshold as set by BrickletHumidity#set_humidity_callback_threshold is reached. The parameter is the humidity of the sensor.

If the threshold keeps being reached, the callback is triggered periodically with the period as set by BrickletHumidity#set_debounce_period.

15
CALLBACK_ANALOG_VALUE_REACHED =

This callback is triggered when the threshold as set by BrickletHumidity#set_analog_value_callback_threshold is reached. The parameter is the analog value of the sensor.

If the threshold keeps being reached, the callback is triggered periodically with the period as set by BrickletHumidity#set_debounce_period.

16
FUNCTION_GET_HUMIDITY =

:nodoc:

1
FUNCTION_GET_ANALOG_VALUE =

:nodoc:

2
FUNCTION_SET_HUMIDITY_CALLBACK_PERIOD =

:nodoc:

3
FUNCTION_GET_HUMIDITY_CALLBACK_PERIOD =

:nodoc:

4
FUNCTION_SET_ANALOG_VALUE_CALLBACK_PERIOD =

:nodoc:

5
FUNCTION_GET_ANALOG_VALUE_CALLBACK_PERIOD =

:nodoc:

6
FUNCTION_SET_HUMIDITY_CALLBACK_THRESHOLD =

:nodoc:

7
FUNCTION_GET_HUMIDITY_CALLBACK_THRESHOLD =

:nodoc:

8
FUNCTION_SET_ANALOG_VALUE_CALLBACK_THRESHOLD =

:nodoc:

9
FUNCTION_GET_ANALOG_VALUE_CALLBACK_THRESHOLD =

:nodoc:

10
FUNCTION_SET_DEBOUNCE_PERIOD =

:nodoc:

11
FUNCTION_GET_DEBOUNCE_PERIOD =

:nodoc:

12
FUNCTION_GET_IDENTITY =

:nodoc:

255
THRESHOLD_OPTION_OFF =

:nodoc:

'x'
THRESHOLD_OPTION_OUTSIDE =

:nodoc:

'o'
THRESHOLD_OPTION_INSIDE =

:nodoc:

'i'
THRESHOLD_OPTION_SMALLER =

:nodoc:

'<'
THRESHOLD_OPTION_GREATER =

:nodoc:

'>'

Constants inherited from Device

Device::DEVICE_IDENTIFIER_CHECK_MATCH, Device::DEVICE_IDENTIFIER_CHECK_MISMATCH, Device::DEVICE_IDENTIFIER_CHECK_PENDING, Device::RESPONSE_EXPECTED_ALWAYS_TRUE, Device::RESPONSE_EXPECTED_FALSE, Device::RESPONSE_EXPECTED_INVALID_FUNCTION_ID, Device::RESPONSE_EXPECTED_TRUE

Instance Attribute Summary

Attributes inherited from Device

#callback_formats, #expected_response_function_id, #expected_response_sequence_number, #high_level_callbacks, #registered_callbacks, #replaced, #uid

Instance Method Summary collapse

Methods inherited from Device

#check_validity, #dequeue_response, #enqueue_response, #get_api_version, #get_response_expected, #send_request, #set_response_expected, #set_response_expected_all

Constructor Details

#initialize(uid, ipcon) ⇒ BrickletHumidity

Creates an object with the unique device ID uid and adds it to the IP Connection ipcon.



74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
# File 'lib/tinkerforge/bricklet_humidity.rb', line 74

def initialize(uid, ipcon)
  super uid, ipcon, DEVICE_IDENTIFIER, DEVICE_DISPLAY_NAME

  @api_version = [2, 0, 1]

  @response_expected[FUNCTION_GET_HUMIDITY] = RESPONSE_EXPECTED_ALWAYS_TRUE
  @response_expected[FUNCTION_GET_ANALOG_VALUE] = RESPONSE_EXPECTED_ALWAYS_TRUE
  @response_expected[FUNCTION_SET_HUMIDITY_CALLBACK_PERIOD] = RESPONSE_EXPECTED_TRUE
  @response_expected[FUNCTION_GET_HUMIDITY_CALLBACK_PERIOD] = RESPONSE_EXPECTED_ALWAYS_TRUE
  @response_expected[FUNCTION_SET_ANALOG_VALUE_CALLBACK_PERIOD] = RESPONSE_EXPECTED_TRUE
  @response_expected[FUNCTION_GET_ANALOG_VALUE_CALLBACK_PERIOD] = RESPONSE_EXPECTED_ALWAYS_TRUE
  @response_expected[FUNCTION_SET_HUMIDITY_CALLBACK_THRESHOLD] = RESPONSE_EXPECTED_TRUE
  @response_expected[FUNCTION_GET_HUMIDITY_CALLBACK_THRESHOLD] = RESPONSE_EXPECTED_ALWAYS_TRUE
  @response_expected[FUNCTION_SET_ANALOG_VALUE_CALLBACK_THRESHOLD] = RESPONSE_EXPECTED_TRUE
  @response_expected[FUNCTION_GET_ANALOG_VALUE_CALLBACK_THRESHOLD] = RESPONSE_EXPECTED_ALWAYS_TRUE
  @response_expected[FUNCTION_SET_DEBOUNCE_PERIOD] = RESPONSE_EXPECTED_TRUE
  @response_expected[FUNCTION_GET_DEBOUNCE_PERIOD] = RESPONSE_EXPECTED_ALWAYS_TRUE
  @response_expected[FUNCTION_GET_IDENTITY] = RESPONSE_EXPECTED_ALWAYS_TRUE

  @callback_formats[CALLBACK_HUMIDITY] = [10, 'S']
  @callback_formats[CALLBACK_ANALOG_VALUE] = [10, 'S']
  @callback_formats[CALLBACK_HUMIDITY_REACHED] = [10, 'S']
  @callback_formats[CALLBACK_ANALOG_VALUE_REACHED] = [10, 'S']

  @ipcon.add_device self
end

Instance Method Details

#get_analog_valueObject

Returns the value as read by a 12-bit analog-to-digital converter.

.. note

The value returned by BrickletHumidity#get_humidity is averaged over several samples to yield less noise, while BrickletHumidity#get_analog_value gives back raw unfiltered analog values. The returned humidity value is calibrated for room temperatures, if you use the sensor in extreme cold or extreme warm environments, you might want to calculate the humidity from the analog value yourself. See the ‘HIH 5030 datasheet <github.com/Tinkerforge/humidity-bricklet/raw/master/datasheets/hih-5030.pdf>`__.

If you want the analog value periodically, it is recommended to use the CALLBACK_ANALOG_VALUE callback and set the period with BrickletHumidity#set_analog_value_callback_period.



126
127
128
129
130
# File 'lib/tinkerforge/bricklet_humidity.rb', line 126

def get_analog_value
  check_validity

  send_request FUNCTION_GET_ANALOG_VALUE, [], '', 10, 'S'
end

#get_analog_value_callback_periodObject

Returns the period as set by BrickletHumidity#set_analog_value_callback_period.



162
163
164
165
166
# File 'lib/tinkerforge/bricklet_humidity.rb', line 162

def get_analog_value_callback_period
  check_validity

  send_request FUNCTION_GET_ANALOG_VALUE_CALLBACK_PERIOD, [], '', 12, 'L'
end

#get_analog_value_callback_thresholdObject

Returns the threshold as set by BrickletHumidity#set_analog_value_callback_threshold.



210
211
212
213
214
# File 'lib/tinkerforge/bricklet_humidity.rb', line 210

def get_analog_value_callback_threshold
  check_validity

  send_request FUNCTION_GET_ANALOG_VALUE_CALLBACK_THRESHOLD, [], '', 13, 'k S S'
end

#get_debounce_periodObject

Returns the debounce period as set by BrickletHumidity#set_debounce_period.



234
235
236
237
238
# File 'lib/tinkerforge/bricklet_humidity.rb', line 234

def get_debounce_period
  check_validity

  send_request FUNCTION_GET_DEBOUNCE_PERIOD, [], '', 12, 'L'
end

#get_humidityObject

Returns the humidity of the sensor.

If you want to get the humidity periodically, it is recommended to use the CALLBACK_HUMIDITY callback and set the period with BrickletHumidity#set_humidity_callback_period.



106
107
108
109
110
# File 'lib/tinkerforge/bricklet_humidity.rb', line 106

def get_humidity
  check_validity

  send_request FUNCTION_GET_HUMIDITY, [], '', 10, 'S'
end

#get_humidity_callback_periodObject

Returns the period as set by BrickletHumidity#set_humidity_callback_period.



144
145
146
147
148
# File 'lib/tinkerforge/bricklet_humidity.rb', line 144

def get_humidity_callback_period
  check_validity

  send_request FUNCTION_GET_HUMIDITY_CALLBACK_PERIOD, [], '', 12, 'L'
end

#get_humidity_callback_thresholdObject

Returns the threshold as set by BrickletHumidity#set_humidity_callback_threshold.



186
187
188
189
190
# File 'lib/tinkerforge/bricklet_humidity.rb', line 186

def get_humidity_callback_threshold
  check_validity

  send_request FUNCTION_GET_HUMIDITY_CALLBACK_THRESHOLD, [], '', 13, 'k S S'
end

#get_identityObject

Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.

The position can be ‘a’, ‘b’, ‘c’, ‘d’, ‘e’, ‘f’, ‘g’ or ‘h’ (Bricklet Port). A Bricklet connected to an :ref:‘Isolator Bricklet <isolator_bricklet>` is always at position ’z’.

The device identifier numbers can be found :ref:‘here <device_identifier>`. |device_identifier_constant|



250
251
252
# File 'lib/tinkerforge/bricklet_humidity.rb', line 250

def get_identity
  send_request FUNCTION_GET_IDENTITY, [], '', 33, 'Z8 Z8 k C3 C3 S'
end

#register_callback(id, &block) ⇒ Object

Registers a callback with ID id to the block block.



255
256
257
258
# File 'lib/tinkerforge/bricklet_humidity.rb', line 255

def register_callback(id, &block)
  callback = block
  @registered_callbacks[id] = callback
end

#set_analog_value_callback_period(period) ⇒ Object

Sets the period with which the CALLBACK_ANALOG_VALUE callback is triggered periodically. A value of 0 turns the callback off.

The CALLBACK_ANALOG_VALUE callback is only triggered if the analog value has changed since the last triggering.



155
156
157
158
159
# File 'lib/tinkerforge/bricklet_humidity.rb', line 155

def set_analog_value_callback_period(period)
  check_validity

  send_request FUNCTION_SET_ANALOG_VALUE_CALLBACK_PERIOD, [period], 'L', 8, ''
end

#set_analog_value_callback_threshold(option, min, max) ⇒ Object

Sets the thresholds for the CALLBACK_ANALOG_VALUE_REACHED callback.

The following options are possible:

"Option", "Description"

"'x'",    "Callback is turned off"
"'o'",    "Callback is triggered when the analog value is *outside* the min and max values"
"'i'",    "Callback is triggered when the analog value is *inside* the min and max values"
"'<'",    "Callback is triggered when the analog value is smaller than the min value (max is ignored)"
"'>'",    "Callback is triggered when the analog value is greater than the min value (max is ignored)"


203
204
205
206
207
# File 'lib/tinkerforge/bricklet_humidity.rb', line 203

def set_analog_value_callback_threshold(option, min, max)
  check_validity

  send_request FUNCTION_SET_ANALOG_VALUE_CALLBACK_THRESHOLD, [option, min, max], 'k S S', 8, ''
end

#set_debounce_period(debounce) ⇒ Object

Sets the period with which the threshold callbacks

  • CALLBACK_HUMIDITY_REACHED,

  • CALLBACK_ANALOG_VALUE_REACHED

are triggered, if the thresholds

  • BrickletHumidity#set_humidity_callback_threshold,

  • BrickletHumidity#set_analog_value_callback_threshold

keep being reached.



227
228
229
230
231
# File 'lib/tinkerforge/bricklet_humidity.rb', line 227

def set_debounce_period(debounce)
  check_validity

  send_request FUNCTION_SET_DEBOUNCE_PERIOD, [debounce], 'L', 8, ''
end

#set_humidity_callback_period(period) ⇒ Object

Sets the period with which the CALLBACK_HUMIDITY callback is triggered periodically. A value of 0 turns the callback off.

The CALLBACK_HUMIDITY callback is only triggered if the humidity has changed since the last triggering.



137
138
139
140
141
# File 'lib/tinkerforge/bricklet_humidity.rb', line 137

def set_humidity_callback_period(period)
  check_validity

  send_request FUNCTION_SET_HUMIDITY_CALLBACK_PERIOD, [period], 'L', 8, ''
end

#set_humidity_callback_threshold(option, min, max) ⇒ Object

Sets the thresholds for the CALLBACK_HUMIDITY_REACHED callback.

The following options are possible:

"Option", "Description"

"'x'",    "Callback is turned off"
"'o'",    "Callback is triggered when the humidity is *outside* the min and max values"
"'i'",    "Callback is triggered when the humidity is *inside* the min and max values"
"'<'",    "Callback is triggered when the humidity is smaller than the min value (max is ignored)"
"'>'",    "Callback is triggered when the humidity is greater than the min value (max is ignored)"


179
180
181
182
183
# File 'lib/tinkerforge/bricklet_humidity.rb', line 179

def set_humidity_callback_threshold(option, min, max)
  check_validity

  send_request FUNCTION_SET_HUMIDITY_CALLBACK_THRESHOLD, [option, min, max], 'k S S', 8, ''
end