Class: BTAP::Resources::HVAC::Plant::PlantTests
- Inherits:
-
Test::Unit::TestCase
- Object
- Test::Unit::TestCase
- BTAP::Resources::HVAC::Plant::PlantTests
- Defined in:
- lib/openstudio-standards/btap/hvac.rb
Instance Method Summary collapse
- #test_add_air_loop ⇒ Object
- #test_add_boiler_hot_water_to_water_loop ⇒ Object
- #test_add_chiller_electric_eir_to_water_loop ⇒ Object
- #test_add_cooling_tower_to_water_loop ⇒ Object
- #test_add_district_cooling_to_water_loop ⇒ Object
- #test_add_district_heating_to_water_loop ⇒ Object
- #test_add_pump_variable_speed_to_water_loop ⇒ Object
- #test_add_water_loop ⇒ Object
Instance Method Details
#test_add_air_loop ⇒ Object
139 140 141 142 143 |
# File 'lib/openstudio-standards/btap/hvac.rb', line 139 def test_add_air_loop() model = OpenStudio::Model::Model.new() loop = BTAP::Resources::HVAC::Plant::add_air_loop(model) assert( !(loop.to_AirLoopHVAC.empty?)) end |
#test_add_boiler_hot_water_to_water_loop ⇒ Object
145 146 147 148 149 150 |
# File 'lib/openstudio-standards/btap/hvac.rb', line 145 def test_add_boiler_hot_water_to_water_loop() model = OpenStudio::Model::Model.new() loop = BTAP::Resources::HVAC::Plant::add_water_loop(model) boiler = BTAP::Resources::HVAC::Plant::add_boiler_hot_water_to_water_loop(model,loop) assert( !(boiler.to_BoilerHotWater.empty?)) end |
#test_add_chiller_electric_eir_to_water_loop ⇒ Object
159 160 161 162 163 164 |
# File 'lib/openstudio-standards/btap/hvac.rb', line 159 def test_add_chiller_electric_eir_to_water_loop() model = OpenStudio::Model::Model.new() loop = BTAP::Resources::HVAC::Plant::add_water_loop(model) chiller = BTAP::Resources::HVAC::Plant::add_chiller_electric_eir_to_water_loop(model,loop ) assert( !(chiller.to_ChillerElectricEIR.empty?)) end |
#test_add_cooling_tower_to_water_loop ⇒ Object
152 153 154 155 156 157 |
# File 'lib/openstudio-standards/btap/hvac.rb', line 152 def test_add_cooling_tower_to_water_loop() model = OpenStudio::Model::Model.new() loop = BTAP::Resources::HVAC::Plant::add_water_loop(model) tower = BTAP::Resources::HVAC::Plant::add_cooling_tower_to_water_loop(model,loop ) assert( !(tower.to_CoolingTowerSingleSpeed.empty?)) end |
#test_add_district_cooling_to_water_loop ⇒ Object
173 174 175 176 177 178 |
# File 'lib/openstudio-standards/btap/hvac.rb', line 173 def test_add_district_cooling_to_water_loop() model = OpenStudio::Model::Model.new() loop = BTAP::Resources::HVAC::Plant::add_water_loop(model) des = BTAP::Resources::HVAC::Plant::add_district_cooling_to_water_loop(model,loop ) assert( !(des.to_DistrictCooling.empty?)) end |
#test_add_district_heating_to_water_loop ⇒ Object
166 167 168 169 170 171 |
# File 'lib/openstudio-standards/btap/hvac.rb', line 166 def test_add_district_heating_to_water_loop() model = OpenStudio::Model::Model.new() loop = BTAP::Resources::HVAC::Plant::add_water_loop(model) des = BTAP::Resources::HVAC::Plant::add_district_heating_to_water_loop(model,loop ) assert( !(des.to_DistrictHeating.empty?)) end |
#test_add_pump_variable_speed_to_water_loop ⇒ Object
180 181 182 183 184 185 |
# File 'lib/openstudio-standards/btap/hvac.rb', line 180 def test_add_pump_variable_speed_to_water_loop() model = OpenStudio::Model::Model.new() water_loop = BTAP::Resources::HVAC::Plant::add_water_loop(model) pump = BTAP::Resources::HVAC::Plant::add_pump_variable_speed(model, water_loop) assert( !(pump.to_PumpVariableSpeed.empty?)) end |
#test_add_water_loop ⇒ Object
133 134 135 136 137 |