14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
|
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb', line 14
def model_custom_daylighting_tweaks(building_type, climate_zone, prototype_input, model)
OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Adjusting daylight sensor positions and fractions')
adjustments = case climate_zone
when 'ASHRAE 169-2006-6A',
'ASHRAE 169-2006-6B',
'ASHRAE 169-2006-7A',
'ASHRAE 169-2006-8A',
'ASHRAE 169-2013-6A',
'ASHRAE 169-2013-6B',
'ASHRAE 169-2013-7A',
'ASHRAE 169-2013-8A'
[
{ '90.1-2010' => { 'Zone3 Bulk Storage' => { 'sensor_1_frac' => 0.116,
'sensor_1_xyz' => [6.096, 45.718514, 0] },
'Zone1 Office' => { 'sensor_1_frac' => 0.11,
'sensor_2_frac' => 0.11,
'sensor_1_xyz' => [2.4384, 2.4384, 0.762],
'sensor_2_xyz' => [20.4216, 1.6154, 0.762] } },
'90.1-2013' => { 'Zone3 Bulk Storage' => { 'sensor_1_frac' => 0.116,
'sensor_1_xyz' => [6.096, 45.718514, 0] },
'Zone1 Office' => { 'sensor_1_frac' => 0.29,
'sensor_2_frac' => 0.1,
'sensor_1_xyz' => [3.2675, 4.5718, 0.762],
'sensor_2_xyz' => [20.4216, 4.5718, 0.762] } },
'90.1-2016' => { 'Zone3 Bulk Storage' => { 'sensor_1_frac' => 0.116,
'sensor_1_xyz' => [6.096, 45.718514, 0] },
'Zone1 Office' => { 'sensor_1_frac' => 0.29,
'sensor_2_frac' => 0.1,
'sensor_1_xyz' => [3.2675, 4.5718, 0.762],
'sensor_2_xyz' => [20.4216, 4.5718, 0.762] } },
'90.1-2019' => { 'Zone3 Bulk Storage' => { 'sensor_1_frac' => 0.116,
'sensor_1_xyz' => [6.096, 45.718514, 0] },
'Zone1 Office' => { 'sensor_1_frac' => 0.29,
'sensor_2_frac' => 0.1,
'sensor_1_xyz' => [3.2675, 4.5718, 0.762],
'sensor_2_xyz' => [20.4216, 4.5718, 0.762] } } }
]
else
[
{ '90.1-2010' => { 'Zone3 Bulk Storage' => { 'sensor_1_frac' => 0.25,
'sensor_2_frac' => 0.25,
'sensor_1_xyz' => [22.9, 48, 0],
'sensor_2_xyz' => [22.9, 34.7, 0] },
'Zone2 Fine Storage' => { 'sensor_1_frac' => 0.25,
'sensor_2_frac' => 0.25,
'sensor_1_xyz' => [27.8892, 24.9936, 0.762],
'sensor_2_xyz' => [3.81, 24.9936, 0.762] } },
'90.1-2013' => { 'Zone1 Office' => { 'sensor_1_frac' => 0.29,
'sensor_2_frac' => 0.1,
'sensor_1_xyz' => [3.2675, 4.5718, 0.762],
'sensor_2_xyz' => [20.4216, 4.5718, 0.762] },
'Zone3 Bulk Storage' => { 'sensor_1_frac' => 0.25,
'sensor_2_frac' => 0.25,
'sensor_1_xyz' => [22.9, 48, 0],
'sensor_2_xyz' => [22.9, 34.7, 0] },
'Zone2 Fine Storage' => { 'sensor_1_frac' => 0.25,
'sensor_2_frac' => 0.25,
'sensor_1_xyz' => [27.8892, 24.9936, 0.762],
'sensor_2_xyz' => [3.81, 24.9936, 0.762] } },
'90.1-2016' => { 'Zone1 Office' => { 'sensor_1_frac' => 0.29,
'sensor_2_frac' => 0.1,
'sensor_1_xyz' => [3.2675, 4.5718, 0.762],
'sensor_2_xyz' => [20.4216, 4.5718, 0.762] },
'Zone3 Bulk Storage' => { 'sensor_1_frac' => 0.25,
'sensor_2_frac' => 0.25,
'sensor_1_xyz' => [22.9, 48, 0],
'sensor_2_xyz' => [22.9, 34.7, 0] },
'Zone2 Fine Storage' => { 'sensor_1_frac' => 0.25,
'sensor_2_frac' => 0.25,
'sensor_1_xyz' => [27.8892, 24.9936, 0.762],
'sensor_2_xyz' => [3.81, 24.9936, 0.762] } },
'90.1-2019' => { 'Zone1 Office' => { 'sensor_1_frac' => 0.29,
'sensor_2_frac' => 0.1,
'sensor_1_xyz' => [3.2675, 4.5718, 0.762],
'sensor_2_xyz' => [20.4216, 4.5718, 0.762] },
'Zone3 Bulk Storage' => { 'sensor_1_frac' => 0.25,
'sensor_2_frac' => 0.25,
'sensor_1_xyz' => [22.9, 48, 0],
'sensor_2_xyz' => [22.9, 34.7, 0] },
'Zone2 Fine Storage' => { 'sensor_1_frac' => 0.25,
'sensor_2_frac' => 0.25,
'sensor_1_xyz' => [27.8892, 24.9936, 0.762],
'sensor_2_xyz' => [3.81, 24.9936, 0.762] } } }
]
end
model.getSpaces.each do |space|
if adjustments[0].keys.include? template
if adjustments[0][template].keys.include? space.name.to_s
adj = adjustments[0][template][space.name.to_s]
next if space.thermalZone.empty?
zone = space.thermalZone.get
next if space.spaceType.empty?
spc_type = space.spaceType.get
next if spc_type.standardsSpaceType.empty?
stds_spc_type = spc_type.standardsSpaceType.get
if adj['sensor_1_frac']
if !zone.primaryDaylightingControl.is_initialized
puts zone
sensor_1 = OpenStudio::Model::DaylightingControl.new(space.model)
sensor_1.setName("#{space.name} Daylt Sensor 2")
sensor_1.setSpace(space)
sensor_1.setIlluminanceSetpoint(375)
sensor_1.setLightingControlType('Stepped')
sensor_1.setNumberofSteppedControlSteps(3) sensor_1.setMinimumInputPowerFractionforContinuousDimmingControl(0.3)
sensor_1.setMinimumLightOutputFractionforContinuousDimmingControl(0.2)
sensor_1.setProbabilityLightingwillbeResetWhenNeededinManualSteppedControl(1.0)
sensor_1.setMaximumAllowableDiscomfortGlareIndex(22.0)
zone.setPrimaryDaylightingControl(sensor_1)
end
OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', "For #{zone.name}: Adjusting primary daylight sensor to control #{adj['sensor_1_frac']} of the lighting.")
zone.setFractionofZoneControlledbyPrimaryDaylightingControl(adj['sensor_1_frac'])
pri_ctrl = zone.primaryDaylightingControl.get
if adj['sensor_1_xyz']
x = adj['sensor_1_xyz'][0]
y = adj['sensor_1_xyz'][1]
z = adj['sensor_1_xyz'][2]
OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', "For #{zone.name}: Adjusting primary daylight sensor position to [#{x}, #{y}, #{z}].")
pri_ctrl.setPositionXCoordinate(x)
pri_ctrl.setPositionYCoordinate(y)
pri_ctrl.setPositionZCoordinate(z)
end
end
if adj['sensor_2_frac']
if !zone.secondaryDaylightingControl.is_initialized
sensor_2 = OpenStudio::Model::DaylightingControl.new(space.model)
sensor_2.setName("#{space.name} Daylt Sensor 2")
sensor_2.setSpace(space)
sensor_2.setIlluminanceSetpoint(375)
sensor_2.setLightingControlType('Stepped')
sensor_2.setNumberofSteppedControlSteps(3) sensor_2.setMinimumInputPowerFractionforContinuousDimmingControl(0.3)
sensor_2.setMinimumLightOutputFractionforContinuousDimmingControl(0.2)
sensor_2.setProbabilityLightingwillbeResetWhenNeededinManualSteppedControl(1.0)
sensor_2.setMaximumAllowableDiscomfortGlareIndex(22.0)
zone.setSecondaryDaylightingControl(sensor_2)
end
OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', "For #{zone.name}: Adjusting secondary daylight sensor to control #{adj['sensor_2_frac']} of the lighting.")
zone.setFractionofZoneControlledbySecondaryDaylightingControl(adj['sensor_2_frac'])
sec_ctrl = zone.secondaryDaylightingControl.get
if adj['sensor_2_xyz']
x = adj['sensor_2_xyz'][0]
y = adj['sensor_2_xyz'][1]
z = adj['sensor_2_xyz'][2]
OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', "For #{zone.name}: Adjusting secondary daylight sensor position to [#{x}, #{y}, #{z}].")
sec_ctrl.setPositionXCoordinate(x)
sec_ctrl.setPositionYCoordinate(y)
sec_ctrl.setPositionZCoordinate(z)
end
end
end
end
end
end
|