Module: Hospital

Defined in:
lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb

Overview

Custom changes for the Hospital prototype. These are changes that are inconsistent with other prototype building types.

Instance Method Summary collapse

Instance Method Details

#add_extra_equip_kitchen(model) ⇒ Object

add extra equipment for kitchen



128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb', line 128

def add_extra_equip_kitchen(model)
  kitchen_space = model.getSpaceByName('Kitchen_Flr_5')
  kitchen_space = kitchen_space.get
  kitchen_space_type = kitchen_space.spaceType.get
  elec_equip_def1 = OpenStudio::Model::ElectricEquipmentDefinition.new(model)
  elec_equip_def2 = OpenStudio::Model::ElectricEquipmentDefinition.new(model)
  elec_equip_def1.setName('Kitchen Electric Equipment Definition1')
  elec_equip_def2.setName('Kitchen Electric Equipment Definition2')
  case template
    when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
      elec_equip_def1.setFractionLatent(0)
      elec_equip_def1.setFractionRadiant(0.25)
      elec_equip_def1.setFractionLost(0)
      elec_equip_def2.setFractionLatent(0)
      elec_equip_def2.setFractionRadiant(0.25)
      elec_equip_def2.setFractionLost(0)
      if template == '90.1-2013' || template == '90.1-2016' || template == '90.1-2019'
        elec_equip_def1.setDesignLevel(915)
        elec_equip_def2.setDesignLevel(855)
      else
        elec_equip_def1.setDesignLevel(915)
        elec_equip_def2.setDesignLevel(855)
      end
      # Create the electric equipment instance and hook it up to the space type
      elec_equip1 = OpenStudio::Model::ElectricEquipment.new(elec_equip_def1)
      elec_equip2 = OpenStudio::Model::ElectricEquipment.new(elec_equip_def2)
      elec_equip1.setName('Kitchen_Reach-in-Freezer')
      elec_equip2.setName('Kitchen_Reach-in-Refrigerator')
      elec_equip1.setSpaceType(kitchen_space_type)
      elec_equip2.setSpaceType(kitchen_space_type)
      elec_equip1.setSchedule(model_add_schedule(model, 'Hospital ALWAYS_ON'))
      elec_equip2.setSchedule(model_add_schedule(model, 'Hospital ALWAYS_ON'))
  end
end

#add_humidifier(space_name, hot_water_loop, model) ⇒ Object



212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb', line 212

def add_humidifier(space_name, hot_water_loop, model)
  space = model.getSpaceByName(space_name).get
  zone = space.thermalZone.get
  humidistat = OpenStudio::Model::ZoneControlHumidistat.new(model)
  humidistat.setHumidifyingRelativeHumiditySetpointSchedule(model_add_schedule(model, 'Hospital MinRelHumSetSch'))
  humidistat.setDehumidifyingRelativeHumiditySetpointSchedule(model_add_schedule(model, 'Hospital MaxRelHumSetSch'))
  zone.setZoneControlHumidistat(humidistat)

  model.getAirLoopHVACs.sort.each do |air_loop|
    if air_loop.thermalZones.include? zone
      humidifier = OpenStudio::Model::HumidifierSteamElectric.new(model)
      humidifier.setRatedCapacity(3.72E-5)
      humidifier.setRatedPower(100_000)
      humidifier.setName("#{air_loop.name.get} Electric Steam Humidifier")
      # get the water heating coil and add humidifier to the outlet of heating coil (right before fan)
      htg_coil = nil
      air_loop.supplyComponents.each do |equip|
        if equip.to_CoilHeatingWater.is_initialized
          htg_coil = equip.to_CoilHeatingWater.get
        end
      end
      heating_coil_outlet_node = htg_coil.airOutletModelObject.get.to_Node.get
      supply_outlet_node = air_loop.supplyOutletNode
      humidifier.addToNode(heating_coil_outlet_node)
      humidity_spm = OpenStudio::Model::SetpointManagerSingleZoneHumidityMinimum.new(model)
      case template
      when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
        create_coil_heating_electric(model,
                                     air_loop_node: supply_outlet_node,
                                     name: "#{space_name} Electric Htg Coil")
        create_coil_heating_water(model,
                                  hot_water_loop,
                                  air_loop_node: supply_outlet_node,
                                  name: "#{space_name} Water Htg Coil")
      end
      # humidity_spm.addToNode(supply_outlet_node)
      humidity_spm.addToNode(humidifier.outletModelObject.get.to_Node.get)
      humidity_spm.setControlZone(zone)
    end
  end
end

#air_loop_hvac_supply_air_temperature_reset_type(air_loop_hvac) ⇒ String

Type of SAT reset for this building type

Parameters:

  • air_loop_hvac (OpenStudio::model::AirLoopHVAC)

    Airloop

Returns:

  • (String)

    Returns type of SAT reset



347
348
349
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb', line 347

def air_loop_hvac_supply_air_temperature_reset_type(air_loop_hvac)
  return 'oa'
end

#air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area) ⇒ Object



334
335
336
337
338
339
340
341
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb', line 334

def air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area)
  min_damper_position = template == '90.1-2010' || template == '90.1-2013' || template == '90.1-2016' || template == '90.1-2019' ? 0.2 : 0.3

  # Set the minimum flow fraction
  air_terminal_single_duct_vav_reheat.setConstantMinimumAirFlowFraction(min_damper_position)

  return true
end

#model_add_daylighting_controls(model) ⇒ Object



254
255
256
257
258
259
260
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb', line 254

def model_add_daylighting_controls(model)
  space_names = ['Office1_Flr_5', 'Office3_Flr_5', 'Lobby_Records_Flr_1']
  space_names.each do |space_name|
    space = model.getSpaceByName(space_name).get
    space_add_daylighting_controls(space, false, false)
  end
end

#model_adjust_vav_minimum_damper(model) ⇒ Object

For operating room 1&2 in 2010 and 2013, VAV minimum air flow is set by schedule



263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb', line 263

def model_adjust_vav_minimum_damper(model)
  model.getThermalZones.each do |zone|
    air_terminal = zone.airLoopHVACTerminal
    if air_terminal.is_initialized
      air_terminal = air_terminal.get
      if air_terminal.to_AirTerminalSingleDuctVAVReheat.is_initialized
        air_terminal = air_terminal.to_AirTerminalSingleDuctVAVReheat.get
        vav_name = air_terminal.name.get
        # High OA zones
        # Determine whether or not to use the high minimum guess.
        # Cutoff was determined by correlating apparent minimum guesses
        # to OA rates in prototypes since not well documented in papers.
        zone_oa_per_area = thermal_zone_outdoor_airflow_rate_per_area(zone)
        airlp = air_terminal.airLoopHVAC.get
        case template
        when 'DOE Ref Pre-1980', 'DOE Ref 1980-2004'
          if vav_name.include?('PatRoom') || vav_name.include?('OR') || vav_name.include?('ICU') || vav_name.include?('Lab') || vav_name.include?('ER') || vav_name.include?('Kitchen')
            air_terminal.setConstantMinimumAirFlowFraction(1.0)
          end
        # Minimum damper position for Outpatient prototype
        # Based on AIA 2001 ventilation requirements
        # See Section 5.2.2.16 in Thornton et al. 2010
        # https://www.energycodes.gov/sites/default/files/documents/BECP_Energy_Cost_Savings_STD2010_May2011_v00.pdf
        when '90.1-2004', '90.1-2007'
          air_terminal.setConstantMinimumAirFlowFraction(1.0) unless airlp.name.to_s.include?('VAV_1') || airlp.name.to_s.include?('VAV_2')
        when '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
          air_terminal.setConstantMinimumAirFlowFraction(1.0) unless airlp.name.to_s.include?('VAV_1') || airlp.name.to_s.include?('VAV_2')
          air_terminal.setConstantMinimumAirFlowFraction(0.5) if vav_name.include? 'PatRoom'
        end
      end
    end
  end
end

#model_custom_geometry_tweaks(building_type, climate_zone, prototype_input, model) ⇒ Object



327
328
329
330
331
332
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb', line 327

def model_custom_geometry_tweaks(building_type, climate_zone, prototype_input, model)
  # Set original building North axis
  model_set_building_north_axis(model, 0.0)

  return true
end

#model_custom_hvac_tweaks(building_type, climate_zone, prototype_input, model) ⇒ Object



5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb', line 5

def model_custom_hvac_tweaks(building_type, climate_zone, prototype_input, model)
  OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Started building type specific HVAC adjustments')

  # add transformer
  # efficiency based on a 500 kVA transformer
  case template
  when '90.1-2004', '90.1-2007'
    transformer_efficiency = 0.979
  when '90.1-2010', '90.1-2013'
    transformer_efficiency = 0.987
  when '90.1-2016', '90.1-2019'
    transformer_efficiency = 0.991
  else
    transformer_efficiency = nil
  end

  unless transformer_efficiency.nil?
    model_add_transformer(model,
                          wired_lighting_frac: 0.022,
                          transformer_size: 500000,
                          transformer_efficiency: transformer_efficiency)
  end

  # add extra equipment for kitchen
  add_extra_equip_kitchen(model)

  system_to_space_map = define_hvac_system_map(building_type, climate_zone)

  hot_water_loop = nil
  model.getPlantLoops.sort.each do |loop|
    # If it has a boiler:hotwater, it is the correct loop
    unless loop.supplyComponents('OS:Boiler:HotWater'.to_IddObjectType).empty?
      hot_water_loop = loop
    end
  end
  if hot_water_loop
    case template
      when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
        space_names = ['ER_Exam3_Mult4_Flr_1', 'OR2_Mult5_Flr_2', 'ICU_Flr_2', 'PatRoom5_Mult10_Flr_4', 'Lab_Flr_3']
        space_names.each do |space_name|
          add_humidifier(space_name, hot_water_loop, model)
        end
      when 'DOE Ref Pre-1980', 'DOE Ref 1980-2004'
        space_names = ['ER_Exam3_Mult4_Flr_1', 'OR2_Mult5_Flr_2']
        space_names.each do |space_name|
          add_humidifier(space_name, hot_water_loop, model)
        end
    end
  else
    OpenStudio.logFree(OpenStudio::Warn, 'openstudio.model.Model', 'Could not find hot water loop to attach humidifier to.')
  end

  # adjust minimum damper positions
  model_adjust_vav_minimum_damper(model)

  reset_kitchen_oa(model)
  model_update_exhaust_fan_efficiency(model)
  model_reset_or_room_vav_minimum_damper(prototype_input, model)

  # adjust CAV system sizing
  model.getAirLoopHVACs.each do |air_loop|
    if air_loop.name.to_s.include? 'CAV_KITCHEN'
      # system sizing
      sizing_system = air_loop.sizingSystem
      prehtg_sa_temp_c = OpenStudio.convert(55.04, 'F', 'C').get
      htg_sa_temp_c = OpenStudio.convert(104.0, 'F', 'C').get
      sizing_system.setPreheatDesignTemperature(prehtg_sa_temp_c)
      sizing_system.setCentralHeatingDesignSupplyAirTemperature(htg_sa_temp_c)
      sizing_system.setSizingOption('NonCoincident')

      # set coil sizing
      htg_coil = model.getCoilHeatingWaterByName('CAV_KITCHEN Main Htg Coil').get
      htg_coil.setRatedInletAirTemperature(prehtg_sa_temp_c)
      htg_coil.setRatedOutletAirTemperature(htg_sa_temp_c)

      # replace main supply air fan
      air_loop.supplyFan.get.remove
      fan = create_fan_by_name(model,
                               'Hospital_CAV_Sytem_Fan',
                               fan_name: "#{air_loop.name} Fan",
                               end_use_subcategory: 'CAV System Fans')
      fan.setAvailabilitySchedule(model.alwaysOnDiscreteSchedule)
      fan.addToNode(air_loop.supplyOutletNode)

      # replace AirTerminalSingleDuctVAVReheat with AirTerminalSingleDuctUncontrolled
      air_loop.thermalZones.each do |zone|
        # remove old terminal and reheat coil
        old_terminal = zone.airLoopHVACTerminal.get.to_AirTerminalSingleDuctVAVReheat.get
        reheat_coil = old_terminal.reheatCoil
        reheat_coil.remove
        # in future, may need to remove plant loop if empty at end of this
        old_terminal.remove
        air_loop.removeBranchForZone(zone)

        # make new terminal
        new_terminal = OpenStudio::Model::AirTerminalSingleDuctUncontrolled.new(model, model.alwaysOnDiscreteSchedule)
        new_terminal.setName("#{zone.name} CAV Terminal")
        air_loop.addBranchForZone(zone, new_terminal.to_StraightComponent)
        zone.setCoolingPriority(new_terminal.to_ModelObject.get, 1)
        zone.setHeatingPriority(new_terminal.to_ModelObject.get, 1)
      end

      # zone sizing
      zone_htg_sa_temp_c = OpenStudio.convert(104.0, 'F', 'C').get
      air_loop.thermalZones.each do |zone|
        sizing_zone = zone.sizingZone
        sizing_zone.setZoneHeatingDesignSupplyAirTemperature(zone_htg_sa_temp_c)
      end
    end
  end

  # Modify the condenser water pump
  if template == 'DOE Ref 1980-2004' || template == 'DOE Ref Pre-1980'
    cw_pump = model.getPumpConstantSpeedByName('Condenser Water Loop Constant Pump').get
    cw_pump_head_ft_h2o = 60.0
    cw_pump_head_press_pa = OpenStudio.convert(cw_pump_head_ft_h2o, 'ftH_{2}O', 'Pa').get
    cw_pump.setRatedPumpHead(cw_pump_head_press_pa)
  end

  return true
end

#model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Object



177
178
179
180
181
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb', line 177

def model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input)
  update_waterheater_ambient_parameters(model)

  return true
end

#model_modify_oa_controller(model) ⇒ Object



316
317
318
319
320
321
322
323
324
325
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb', line 316

def model_modify_oa_controller(model)
  model.getAirLoopHVACs.sort.each do |air_loop|
    oa_sys = air_loop.airLoopHVACOutdoorAirSystem.get
    oa_control = oa_sys.getControllerOutdoorAir
    case air_loop.name.get
      when 'VAV_ER', 'VAV_ICU', 'VAV_LABS', 'VAV_OR', 'VAV_PATRMS', 'CAV_1', 'CAV_2'
        oa_control.setEconomizerControlType('NoEconomizer')
    end
  end
end

#model_reset_or_room_vav_minimum_damper(prototype_input, model) ⇒ Object



297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb', line 297

def model_reset_or_room_vav_minimum_damper(prototype_input, model)
  case template
  when '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
    model.getAirTerminalSingleDuctVAVReheats.sort.each do |air_terminal|
      air_terminal_name = air_terminal.name.get
      if air_terminal_name.include?('OR1') || air_terminal_name.include?('OR2') || air_terminal_name.include?('OR3') || air_terminal_name.include?('OR4')
        if model.version < OpenStudio::VersionString.new('3.0.1')
          air_terminal.setZoneMinimumAirFlowMethod('Scheduled')
        else
          air_terminal.setZoneMinimumAirFlowInputMethod('Scheduled')
        end
        air_terminal.setMinimumAirFlowFractionSchedule(model_add_schedule(model, 'Hospital OR_MinSA_Sched'))
      end
    end
  else
    return true
  end
end

#model_update_exhaust_fan_efficiency(model) ⇒ Object



197
198
199
200
201
202
203
204
205
206
207
208
209
210
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb', line 197

def model_update_exhaust_fan_efficiency(model)
  case template
    when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
      model.getFanZoneExhausts.sort.each do |exhaust_fan|
        exhaust_fan.setFanEfficiency(0.16)
        exhaust_fan.setPressureRise(125)
      end
    when 'DOE Ref Pre-1980', 'DOE Ref 1980-2004'
      model.getFanZoneExhausts.sort.each do |exhaust_fan|
        exhaust_fan.setFanEfficiency(0.338)
        exhaust_fan.setPressureRise(125)
      end
  end
end

#reset_kitchen_oa(model) ⇒ Object

add swh



184
185
186
187
188
189
190
191
192
193
194
195
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb', line 184

def reset_kitchen_oa(model)
  space_kitchen = model.getSpaceByName('Kitchen_Flr_5').get
  ventilation = space_kitchen.designSpecificationOutdoorAir.get
  ventilation.setOutdoorAirFlowperPerson(0)
  ventilation.setOutdoorAirFlowperFloorArea(0)
  case template
    when '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
      ventilation.setOutdoorAirFlowRate(3.398)
    when '90.1-2004', '90.1-2007', 'DOE Ref Pre-1980', 'DOE Ref 1980-2004'
      ventilation.setOutdoorAirFlowRate(3.776)
  end
end

#update_waterheater_ambient_parameters(model) ⇒ Object



163
164
165
166
167
168
169
170
171
172
173
174
175
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb', line 163

def update_waterheater_ambient_parameters(model)
  model.getWaterHeaterMixeds.sort.each do |water_heater|
    if water_heater.name.to_s.include?('300gal')
      water_heater.resetAmbientTemperatureSchedule
      water_heater.setAmbientTemperatureIndicator('ThermalZone')
      water_heater.setAmbientTemperatureThermalZone(model.getThermalZoneByName('Basement ZN').get)
    elsif water_heater.name.to_s.include?('6.0gal')
      water_heater.resetAmbientTemperatureSchedule
      water_heater.setAmbientTemperatureIndicator('ThermalZone')
      water_heater.setAmbientTemperatureThermalZone(model.getThermalZoneByName('Kitchen_Flr_5 ZN').get)
    end
  end
end