Class: DOERef1980to2004Outpatient
- Inherits:
-
DOERef1980to2004
- Object
- Standard
- ASHRAE901
- DOERef1980to2004
- DOERef1980to2004Outpatient
- Defined in:
- lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb
Overview
This class represents a prototypical DOERef1980to2004 Outpatient.
Constant Summary collapse
- @@building_type =
"Outpatient"
Constants inherited from Standard
Instance Attribute Summary collapse
-
#building_story_map ⇒ Object
Returns the value of attribute building_story_map.
-
#geometry_file ⇒ Object
Returns the value of attribute geometry_file.
-
#lookup_building_type ⇒ Object
Returns the value of attribute lookup_building_type.
-
#prototype_database ⇒ Object
Returns the value of attribute prototype_database.
-
#prototype_input ⇒ Object
Returns the value of attribute prototype_input.
-
#space_type_map ⇒ Object
Returns the value of attribute space_type_map.
-
#system_to_space_map ⇒ Object
Returns the value of attribute system_to_space_map.
Attributes inherited from DOERef1980to2004
Attributes inherited from Standard
#space_multiplier_map, #standards_data, #template
Instance Method Summary collapse
-
#define_building_story_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the building story that they are located on.
-
#define_hvac_system_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the HVAC system that will be applied to those spaces.
-
#define_space_type_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the space types available for this particular Standard.
-
#initialize ⇒ DOERef1980to2004Outpatient
constructor
A new instance of DOERef1980to2004Outpatient.
-
#model_custom_daylighting_tweaks(building_type, climate_zone, prototype_input, model) ⇒ Bool
Makes changes to the daylighting sensors that are too specific to be coded generically.
-
#model_get_lookup_name(building_type) ⇒ String
Get the name of the building type used in lookups.
-
#model_modify_oa_controller(model) ⇒ Object
Does nothing unless implmented by the specific standard.
-
#model_reset_or_room_vav_minimum_damper(prototype_input, model) ⇒ Object
Does nothing unless implmented by the specific standard.
-
#model_update_exhaust_fan_efficiency(model) ⇒ Object
Does nothing unless implmented by the specific standard.
-
#model_update_fan_efficiency(model) ⇒ Object
Does nothing unless implmented by the specific standard.
-
#set_variables ⇒ Object
This method is used to extend the class with building-type-specific methods, as defined in Prototype.SomeBuildingType.rb.
Methods inherited from DOERef1980to2004
#air_loop_hvac_apply_multizone_vav_outdoor_air_sizing, #air_loop_hvac_optimum_start_required?, #air_loop_hvac_static_pressure_reset_required?, #air_loop_hvac_vav_damper_action, #air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position, #load_standards_database, #model_add_elevator, #model_apply_infiltration_standard, #model_elevator_lift_power, #model_get_climate_zone_set_from_list, #model_walkin_freezer_latent_case_credit_curve, #plant_loop_supply_water_temperature_reset_required?
Methods inherited from ASHRAE901
#fan_variable_volume_part_load_fan_power_limitation_capacity_limit, #fan_variable_volume_part_load_fan_power_limitation_hp_limit, #load_standards_database
Methods inherited from Standard
#adjust_infiltration_to_lower_pressure, #adjust_infiltration_to_prototype_building_conditions, #adjust_sizing_system, #afue_to_thermal_eff, #air_loop_hvac_add_motorized_oa_damper, #air_loop_hvac_adjust_minimum_vav_damper_positions, #air_loop_hvac_adjust_minimum_vav_damper_positions_outpatient, #air_loop_hvac_allowable_system_brake_horsepower, #air_loop_hvac_apply_baseline_fan_pressure_rise, #air_loop_hvac_apply_economizer_integration, #air_loop_hvac_apply_economizer_limits, #air_loop_hvac_apply_energy_recovery_ventilator, #air_loop_hvac_apply_energy_recovery_ventilator_efficiency, #air_loop_hvac_apply_maximum_reheat_temperature, #air_loop_hvac_apply_minimum_vav_damper_positions, #air_loop_hvac_apply_multizone_vav_outdoor_air_sizing, #air_loop_hvac_apply_prm_baseline_controls, #air_loop_hvac_apply_prm_baseline_economizer, #air_loop_hvac_apply_prm_baseline_fan_power, #air_loop_hvac_apply_prm_sizing_temperatures, #air_loop_hvac_apply_single_zone_controls, #air_loop_hvac_apply_standard_controls, #air_loop_hvac_apply_vav_damper_action, #air_loop_hvac_data_center_area_served, #air_loop_hvac_dcv_required_when_erv, #air_loop_hvac_demand_control_ventilation_limits, #air_loop_hvac_demand_control_ventilation_required?, #air_loop_hvac_disable_multizone_vav_optimization, #air_loop_hvac_dx_cooling?, #air_loop_hvac_economizer?, #air_loop_hvac_economizer_limits, #air_loop_hvac_economizer_required?, #air_loop_hvac_economizer_type_allowable?, #air_loop_hvac_enable_demand_control_ventilation, #air_loop_hvac_enable_multizone_vav_optimization, #air_loop_hvac_enable_optimum_start, #air_loop_hvac_enable_supply_air_temperature_reset_delta, #air_loop_hvac_enable_supply_air_temperature_reset_outdoor_temperature, #air_loop_hvac_enable_supply_air_temperature_reset_warmest_zone, #air_loop_hvac_enable_unoccupied_fan_shutoff, #air_loop_hvac_energy_recovery?, #air_loop_hvac_energy_recovery_ventilator_flow_limit, #air_loop_hvac_energy_recovery_ventilator_heat_exchanger_type, #air_loop_hvac_energy_recovery_ventilator_required?, #air_loop_hvac_energy_recovery_ventilator_type, #air_loop_hvac_fan_power_limitation_pressure_drop_adjustment_brake_horsepower, #air_loop_hvac_find_design_supply_air_flow_rate, #air_loop_hvac_floor_area_served, #air_loop_hvac_floor_area_served_exterior_zones, #air_loop_hvac_floor_area_served_interior_zones, #air_loop_hvac_get_occupancy_schedule, #air_loop_hvac_humidifier_count, #air_loop_hvac_include_hydronic_cooling_coil?, #air_loop_hvac_include_wshp?, #air_loop_hvac_integrated_economizer_required?, #air_loop_hvac_motorized_oa_damper_limits, #air_loop_hvac_motorized_oa_damper_required?, #air_loop_hvac_multi_stage_dx_cooling?, #air_loop_hvac_multizone_vav_optimization_required?, #air_loop_hvac_multizone_vav_system?, #air_loop_hvac_optimum_start_required?, #air_loop_hvac_prm_baseline_economizer_required?, #air_loop_hvac_prm_economizer_type_and_limits, #air_loop_hvac_remove_motorized_oa_damper, #air_loop_hvac_residential_area_served, #air_loop_hvac_set_minimum_damper_position, #air_loop_hvac_single_zone_controls_num_stages, #air_loop_hvac_static_pressure_reset_required?, #air_loop_hvac_supply_air_temperature_reset_required?, #air_loop_hvac_supply_return_exhaust_relief_fans, #air_loop_hvac_system_fan_brake_horsepower, #air_loop_hvac_system_multiplier, #air_loop_hvac_terminal_reheat?, #air_loop_hvac_total_cooling_capacity, #air_loop_hvac_unitary_system?, #air_loop_hvac_unoccupied_fan_shutoff_required?, #air_loop_hvac_unoccupied_threshold, #air_loop_hvac_vav_damper_action, #air_loop_hvac_vav_system?, #air_terminal_single_duct_parallel_piu_reheat_apply_prm_baseline_fan_power, #air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position, #air_terminal_single_duct_vav_reheat_apply_minimum_damper_position, #air_terminal_single_duct_vav_reheat_minimum_damper_position, #air_terminal_single_duct_vav_reheat_reheat_type, #air_terminal_single_duct_vav_reheat_set_heating_cap, #apply_changes_to_surface_construction, #apply_lighting_schedule, #apply_limit_to_subsurface_ratio, #apply_max_fdwr, #apply_max_srr, #boiler_hot_water_apply_efficiency_and_curves, #boiler_hot_water_find_capacity, #boiler_hot_water_find_search_criteria, #boiler_hot_water_standard_minimum_thermal_efficiency, build, #building_story_floor_multiplier, #building_story_minimum_z_value, #change_construction_properties_in_model, #chiller_electric_eir_apply_efficiency_and_curves, #chiller_electric_eir_find_capacity, #chiller_electric_eir_find_search_criteria, #chiller_electric_eir_standard_minimum_full_load_efficiency, #coil_cooling_dx_multi_speed_apply_efficiency_and_curves, #coil_cooling_dx_multi_speed_find_capacity, #coil_cooling_dx_multi_speed_standard_minimum_cop, #coil_cooling_dx_single_speed_apply_efficiency_and_curves, #coil_cooling_dx_single_speed_find_capacity, #coil_cooling_dx_single_speed_standard_minimum_cop, #coil_cooling_dx_two_speed_apply_efficiency_and_curves, #coil_cooling_dx_two_speed_find_capacity, #coil_cooling_dx_two_speed_standard_minimum_cop, #coil_cooling_water_to_air_heat_pump_apply_efficiency_and_curves, #coil_cooling_water_to_air_heat_pump_find_capacity, #coil_cooling_water_to_air_heat_pump_standard_minimum_cop, #coil_heating_dx_multi_speed_apply_efficiency_and_curves, #coil_heating_dx_single_speed_apply_defrost_eir_curve_limits, #coil_heating_dx_single_speed_apply_efficiency_and_curves, #coil_heating_dx_single_speed_find_capacity, #coil_heating_dx_single_speed_standard_minimum_cop, #coil_heating_gas_apply_efficiency_and_curves, #coil_heating_gas_apply_prototype_efficiency, #coil_heating_gas_multi_stage_apply_efficiency_and_curves, #coil_heating_gas_multi_stage_find_capacity, #coil_heating_gas_multi_stage_find_search_criteria, #coil_heating_water_to_air_heat_pump_apply_efficiency_and_curves, #coil_heating_water_to_air_heat_pump_find_capacity, #coil_heating_water_to_air_heat_pump_standard_minimum_cop, #combustion_eff_to_thermal_eff, #construction_calculated_solar_heat_gain_coefficient, #construction_calculated_u_factor, #construction_calculated_visible_transmittance, #construction_deep_copy, #construction_set_glazing_shgc, #construction_set_glazing_tvis, #construction_set_glazing_u_value, #construction_set_slab_f_factor, #construction_set_u_value, #construction_set_underground_wall_c_factor, #construction_simple_glazing?, #controller_water_coil_set_convergence_limits, #convert_curve_biquadratic, #cooling_tower_single_speed_apply_efficiency_and_curves, #cooling_tower_two_speed_apply_efficiency_and_curves, #cooling_tower_variable_speed_apply_efficiency_and_curves, #cop_heating_to_cop_heating_no_fan, #cop_to_eer, #cop_to_kw_per_ton, #cop_to_seer_cooling_no_fan, #cop_to_seer_cooling_with_fan, #create_air_conditioner_variable_refrigerant_flow, #create_boiler_hot_water, #create_central_air_source_heat_pump, #create_coil_cooling_dx_single_speed, #create_coil_cooling_dx_two_speed, #create_coil_cooling_water, #create_coil_cooling_water_to_air_heat_pump_equation_fit, #create_coil_heating_dx_single_speed, #create_coil_heating_electric, #create_coil_heating_gas, #create_coil_heating_water, #create_coil_heating_water_to_air_heat_pump_equation_fit, #create_curve_bicubic, #create_curve_biquadratic, #create_curve_cubic, #create_curve_exponent, #create_curve_quadratic, #create_fan_constant_volume, #create_fan_constant_volume_from_json, #create_fan_on_off, #create_fan_on_off_from_json, #create_fan_variable_volume, #create_fan_variable_volume_from_json, #create_fan_zone_exhaust, #create_fan_zone_exhaust_from_json, #day_schedule_equivalent_full_load_hrs, #define_space_multiplier, #eer_to_cop, #fan_constant_volume_airloop_fan_pressure_rise, #fan_constant_volume_apply_prototype_fan_pressure_rise, #fan_on_off_airloop_or_unitary_fan_pressure_rise, #fan_on_off_apply_prototype_fan_pressure_rise, #fan_variable_volume_airloop_fan_pressure_rise, #fan_variable_volume_apply_prototype_fan_pressure_rise, #fan_variable_volume_cooling_system_type, #fan_variable_volume_part_load_fan_power_limitation?, #fan_variable_volume_part_load_fan_power_limitation_capacity_limit, #fan_variable_volume_part_load_fan_power_limitation_hp_limit, #fan_variable_volume_set_control_type, #fan_zone_exhaust_apply_prototype_fan_pressure_rise, #film_coefficients_r_value, #find_and_set_insulation_layer, #find_exposed_conditioned_roof_surfaces, #find_exposed_conditioned_vertical_surfaces, #find_highest_roof_centre, #fluid_cooler_apply_minimum_power_per_flow, #get_outdoor_subsurface_ratio, #headered_pumps_variable_speed_set_control_type, #heat_exchanger_air_to_air_sensible_and_latent_apply_efficiency, #heat_exchanger_air_to_air_sensible_and_latent_apply_prototype_efficiency, #heat_exchanger_air_to_air_sensible_and_latent_apply_prototype_nominal_electric_power, #heat_exchanger_air_to_air_sensible_and_latent_minimum_efficiency, #heat_exchanger_air_to_air_sensible_and_latent_prototype_default_fan_efficiency, #heating_design_outdoor_temperatures, #hspf_to_cop_heating_no_fan, #hspf_to_cop_heating_with_fan, #intialize, #kw_per_ton_to_cop, #load_hvac_map, #load_initial_osm, #load_standards_database, #model_add_baseboard, #model_add_booster_swh_end_uses, #model_add_cav, #model_add_central_air_source_heat_pump, #model_add_chw_loop, #model_add_constant_schedule_ruleset, #model_add_construction, #model_add_construction_set, #model_add_crac, #model_add_crah, #model_add_curve, #model_add_cw_loop, #model_add_data_center_hvac, #model_add_data_center_load, #model_add_daylighting_controls, #model_add_design_days_and_weather_file, #model_add_district_ambient_loop, #model_add_doas, #model_add_doas_cold_supply, #model_add_elevator, #model_add_elevators, #model_add_evap_cooler, #model_add_exhaust_fan, #model_add_four_pipe_fan_coil, #model_add_furnace_central_ac, #model_add_ground_hx_loop, #model_add_ground_temperatures, #model_add_heatpump_water_heater, #model_add_high_temp_radiant, #model_add_hp_loop, #model_add_hvac, #model_add_hvac_system, #model_add_hw_loop, #model_add_ideal_air_loads, #model_add_low_temp_radiant, #model_add_material, #model_add_minisplit_hp, #model_add_piping_losses_to_swh_system, #model_add_prm_baseline_system, #model_add_psz_ac, #model_add_psz_vav, #model_add_ptac, #model_add_pthp, #model_add_pvav, #model_add_pvav_pfp_boxes, #model_add_radiant_proportional_controls, #model_add_refrigeration_case, #model_add_refrigeration_compressor, #model_add_refrigeration_system, #model_add_refrigeration_walkin, #model_add_schedule, #model_add_schedule_type_limits, #model_add_split_ac, #model_add_swh, #model_add_swh_booster, #model_add_swh_end_uses, #model_add_swh_end_uses_by_space, #model_add_swh_end_uses_by_spaceonly, #model_add_swh_loop, #model_add_transformer, #model_add_typical_exterior_lights, #model_add_typical_refrigeration, #model_add_typical_swh, #model_add_unitheater, #model_add_vav_pfp_boxes, #model_add_vav_reheat, #model_add_vrf, #model_add_water_heater, #model_add_water_source_hp, #model_add_waterside_economizer, #model_add_window_ac, #model_add_zone_erv, #model_add_zone_ventilation, #model_apply_hvac_efficiency_standard, #model_apply_infiltration_standard, #model_apply_multizone_vav_outdoor_air_sizing, #model_apply_parametric_schedules, #model_apply_prm_baseline_skylight_to_roof_ratio, #model_apply_prm_baseline_window_to_wall_ratio, #model_apply_prm_construction_types, #model_apply_prm_sizing_parameters, #model_apply_standard_constructions, #model_assign_spaces_to_stories, #model_attach_water_fixtures_to_spaces?, #model_baseline_system_vav_fan_type, #model_create_exterior_lighting_area_length_count_hash, #model_create_prm_baseline_building, #model_create_prm_baseline_building_requires_vlt_sizing_run, #model_create_space_type_hash, #model_create_story_hash, #model_cw_loop_cooling_tower_fan_type, #model_differentiate_primary_secondary_thermal_zones, #model_effective_num_stories, #model_elevator_fan_pwr, #model_elevator_lift_power, #model_elevator_lighting_pct_incandescent, #model_eliminate_outlier_zones, #model_find_and_add_construction, #model_find_ashrae_hot_water_demand, #model_find_climate_zone_set, #model_find_constructions, #model_find_icc_iecc_2015_hot_water_demand, #model_find_icc_iecc_2015_internal_loads, #model_find_object, #model_find_objects, #model_find_prototype_floor_area, #model_find_target_eui, #model_find_target_eui_by_end_use, #model_find_water_heater_capacity_volume_and_parasitic, #model_get_baseline_system_type_by_zone, #model_get_building_climate_zone_and_building_type, #model_get_climate_zone_set_from_list, #model_get_climate_zone_weather_file_map, #model_get_construction_properties, #model_get_construction_set, #model_get_full_weather_file_path, #model_get_monthly_ground_temps_from_stat_file, #model_get_or_add_ambient_water_loop, #model_get_or_add_chilled_water_loop, #model_get_or_add_ground_hx_loop, #model_get_or_add_heat_pump_loop, #model_get_or_add_hot_water_loop, #model_get_story_for_nominal_z_coordinate, #model_group_zones_by_story, #model_infer_hours_of_operation_building, #model_legacy_results_by_end_use_and_fuel_type, #model_make_name, #model_num_stories_spanned, #model_prm_baseline_system_change_fuel_type, #model_prm_baseline_system_group_minimum_area, #model_prm_baseline_system_groups, #model_prm_baseline_system_number, #model_prm_baseline_system_type, #model_prm_skylight_to_roof_ratio_limit, #model_process_results_for_datapoint, #model_remap_office, #model_remove_external_shading_devices, #model_remove_prm_ems_objects, #model_remove_prm_hvac, #model_remove_unused_resource_objects, #model_residential_and_nonresidential_floor_areas, #model_set_climate_zone, #model_setup_parametric_schedules, #model_standards_climate_zone, #model_system_outdoor_air_sizing_vrp_method, #model_typical_display_case_zone, #model_typical_hvac_system_type, #model_typical_walkin_zone, #model_validate_standards_spacetypes_in_model, #model_ventilation_method, #model_walkin_freezer_latent_case_credit_curve, #model_zones_with_occ_and_fuel_type, #planar_surface_apply_standard_construction, #plant_loop_apply_prm_baseline_chilled_water_pumping_type, #plant_loop_apply_prm_baseline_chilled_water_temperatures, #plant_loop_apply_prm_baseline_condenser_water_pumping_type, #plant_loop_apply_prm_baseline_condenser_water_temperatures, #plant_loop_apply_prm_baseline_hot_water_pumping_type, #plant_loop_apply_prm_baseline_hot_water_temperatures, #plant_loop_apply_prm_baseline_pump_power, #plant_loop_apply_prm_baseline_pumping_type, #plant_loop_apply_prm_baseline_temperatures, #plant_loop_apply_prm_number_of_boilers, #plant_loop_apply_prm_number_of_chillers, #plant_loop_apply_prm_number_of_cooling_towers, #plant_loop_apply_standard_controls, #plant_loop_capacity_W_by_maxflow_and_deltaT_forwater, #plant_loop_enable_supply_water_temperature_reset, #plant_loop_find_maximum_loop_flow_rate, #plant_loop_prm_baseline_condenser_water_temperatures, #plant_loop_supply_water_temperature_reset_required?, #plant_loop_swh_loop?, #plant_loop_swh_system_type, #plant_loop_total_cooling_capacity, #plant_loop_total_floor_area_served, #plant_loop_total_heating_capacity, #plant_loop_total_rated_w_per_gpm, #plant_loop_variable_flow_system?, #prototype_apply_condenser_water_temperatures, #prototype_condenser_water_temperatures, #pump_variable_speed_control_type, #pump_variable_speed_get_control_type, #pump_variable_speed_set_control_type, register_standard, #remove_All_Subsurfaces, #remove_HVAC, #remove_air_loops, #remove_all_HVAC, #remove_all_plant_loops, #remove_all_zone_equipment, #remove_plant_loops, #remove_unused_curves, #remove_vrf, #remove_zone_equipment, #rename_air_loop_nodes, #rename_plant_loop_nodes, #safe_load_model, #safe_load_sql, #schedule_apply_parametric_inputs, #schedule_compact_annual_min_max_value, #schedule_constant_annual_equivalent_full_load_hrs, #schedule_constant_annual_min_max_value, #schedule_ruleset_annual_equivalent_full_load_hrs, #schedule_ruleset_annual_hourly_values, #schedule_ruleset_annual_hours_above_value, #schedule_ruleset_annual_min_max_value, #schedule_ruleset_cleanup_profiles, #schedule_ruleset_set_hours_of_operation, #seer_to_cop_cooling_no_fan, #seer_to_cop_cooling_with_fan, #set_VAV_terminals_to_control_for_outdoor_air, #set_Window_To_Wall_Ratio_set_name, #space_add_daylighting_controls, #space_apply_infiltration_rate, #space_conditioning_category, #space_cooled?, #space_daylighted_area_window_width, #space_daylighted_areas, #space_daylighting_control_required?, #space_daylighting_fractions_and_windows, #space_design_internal_load, #space_exterior_wall_and_roof_and_subsurface_area, #space_exterior_wall_and_window_area, #space_get_adjacent_space_with_most_shared_wall_area, #space_get_adjacent_spaces_with_shared_wall_areas, #space_heated?, #space_hours_of_operation, #space_infiltration_rate_75_pa, #space_plenum?, #space_residential?, #space_sidelighting_effective_aperture, #space_skylight_effective_aperture, #space_type_apply_internal_load_schedules, #space_type_apply_internal_loads, #space_type_apply_rendering_color, #space_type_get_construction_properties, #space_type_get_standards_data, #spaces_get_occupancy_schedule, #spaces_hours_of_operation, #standard_design_sizing_temperatures, #standards_lookup_table_first, #standards_lookup_table_many, #strip_model, #sub_surface_component_infiltration_rate, #sub_surface_create_centered_subsurface_from_scaled_surface, #sub_surface_create_scaled_subsurfaces_from_surface, #sub_surface_reduce_area_by_percent_by_raising_sill, #sub_surface_reduce_area_by_percent_by_shrinking_toward_centroid, #sub_surface_vertical_rectangle?, #surface_absolute_azimuth, #surface_cardinal_direction, #surface_component_infiltration_rate, #surface_replace_existing_subsurfaces_with_centered_subsurface, #thermal_eff_to_afue, #thermal_eff_to_comb_eff, #thermal_zone_add_exhaust, #thermal_zone_add_exhaust_fan_dcv, #thermal_zone_add_unconditioned_thermostat, #thermal_zone_apply_prm_baseline_supply_temperatures, #thermal_zone_building_type, #thermal_zone_conditioning_category, #thermal_zone_convert_oa_req_to_per_area, #thermal_zone_cooled?, #thermal_zone_demand_control_ventilation_limits, #thermal_zone_demand_control_ventilation_required?, #thermal_zone_design_internal_load, #thermal_zone_exhaust_fan_dcv_required?, #thermal_zone_floor_area_with_zone_multipliers, #thermal_zone_fossil_hybrid_or_purchased_heat?, #thermal_zone_fossil_or_electric_type, #thermal_zone_get_adjacent_zones_with_shared_wall_areas, #thermal_zone_get_occupancy_schedule, #thermal_zone_heated?, #thermal_zone_infer_system_type, #thermal_zone_majority_space_type, #thermal_zone_mixed_heating_fuel?, #thermal_zone_occupancy_type, #thermal_zone_outdoor_airflow_rate, #thermal_zone_outdoor_airflow_rate_per_area, #thermal_zone_plenum?, #thermal_zone_prm_baseline_cooling_design_supply_temperature, #thermal_zone_prm_baseline_heating_design_supply_temperature, #thermal_zone_residential?, #thermal_zone_vestibule?, #thermal_zones_get_occupancy_schedule, #true?, #validate_initial_model, #water_heater_mixed_apply_efficiency, #water_heater_mixed_apply_prm_baseline_fuel_type, #water_heater_mixed_find_capacity, #zone_hvac_component_apply_prm_baseline_fan_power, #zone_hvac_component_apply_standard_controls, #zone_hvac_component_apply_vestibule_heating_control, #zone_hvac_component_occupancy_ventilation_control, #zone_hvac_component_prm_baseline_fan_efficacy, #zone_hvac_component_vestibule_heating_control_required?, #zone_hvac_unoccupied_threshold
Methods included from PrototypeFan
apply_base_fan_variables, #create_fan_by_name, #get_fan_from_standards, #prototype_fan_apply_prototype_fan_efficiency
Methods included from CoilDX
#coil_dx_find_search_criteria, #coil_dx_heat_pump?, #coil_dx_heating_type, #coil_dx_subcategory
Methods included from CoolingTower
#cooling_tower_apply_minimum_power_per_flow, #cooling_tower_apply_minimum_power_per_flow_gpm_limit
Methods included from Pump
#pump_apply_prm_pressure_rise_and_motor_efficiency, #pump_apply_standard_minimum_motor_efficiency, #pump_brake_horsepower, #pump_motor_horsepower, #pump_pumppower, #pump_rated_w_per_gpm, #pump_standard_minimum_motor_efficiency_and_size
Methods included from Fan
#fan_adjust_pressure_rise_to_meet_fan_power, #fan_apply_standard_minimum_motor_efficiency, #fan_baseline_impeller_efficiency, #fan_brake_horsepower, #fan_change_impeller_efficiency, #fan_change_motor_efficiency, #fan_fanpower, #fan_motor_horsepower, #fan_rated_w_per_cfm, #fan_small_fan?, #fan_standard_minimum_motor_efficiency_and_size
Constructor Details
#initialize ⇒ DOERef1980to2004Outpatient
Returns a new instance of DOERef1980to2004Outpatient.
19067 19068 19069 19070 19071 19072 19073 19074 19075 19076 19077 19078 19079 19080 19081 19082 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 19067 def initialize super() @instvarbuilding_type = @@building_type @prototype_input = self.standards_lookup_table_first(table_name: 'prototype_inputs',search_criteria: {'template' => @template,'building_type' => @@building_type }) if @prototype_input.nil? OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.Model', "Could not find prototype inputs for #{{'template' => @template,'building_type' => @@building_type }}, cannot create model.") raise("Could not find prototype inputs for DOERef1980to2004Outpatient, cannot create model.") return false end @lookup_building_type = self.model_get_lookup_name(@@building_type) #ideally we should map the data required to a instance variable. @geometry_file = 'geometry/' + @prototype_input['geometry_osm'] hvac_map_file = 'geometry/' + @prototype_input['hvac_json'] @system_to_space_map = load_hvac_map(hvac_map_file) self.set_variables() end |
Instance Attribute Details
#building_story_map ⇒ Object
Returns the value of attribute building_story_map.
19065 19066 19067 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 19065 def building_story_map @building_story_map end |
#geometry_file ⇒ Object
Returns the value of attribute geometry_file.
19064 19065 19066 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 19064 def geometry_file @geometry_file end |
#lookup_building_type ⇒ Object
Returns the value of attribute lookup_building_type.
19062 19063 19064 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 19062 def lookup_building_type @lookup_building_type end |
#prototype_database ⇒ Object
Returns the value of attribute prototype_database.
19060 19061 19062 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 19060 def prototype_database @prototype_database end |
#prototype_input ⇒ Object
Returns the value of attribute prototype_input.
19061 19062 19063 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 19061 def prototype_input @prototype_input end |
#space_type_map ⇒ Object
Returns the value of attribute space_type_map.
19063 19064 19065 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 19063 def space_type_map @space_type_map end |
#system_to_space_map ⇒ Object
Returns the value of attribute system_to_space_map.
19066 19067 19068 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 19066 def system_to_space_map @system_to_space_map end |
Instance Method Details
#define_building_story_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the building story that they are located on.
19107 19108 19109 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 19107 def define_building_story_map(building_type, climate_zone) return @building_story_map end |
#define_hvac_system_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the HVAC system that will be applied to those spaces.
19101 19102 19103 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 19101 def define_hvac_system_map(building_type, climate_zone) return @system_to_space_map end |
#define_space_type_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the space types available for this particular Standard.
19095 19096 19097 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 19095 def define_space_type_map(building_type, climate_zone) return @space_type_map end |
#model_custom_daylighting_tweaks(building_type, climate_zone, prototype_input, model) ⇒ Bool
Makes changes to the daylighting sensors that are too specific to be coded generically.
19156 19157 19158 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 19156 def model_custom_daylighting_tweaks(building_type, climate_zone, prototype_input, model) return true end |
#model_get_lookup_name(building_type) ⇒ String
Unify the lookup names and eliminate this method
Get the name of the building type used in lookups
19127 19128 19129 19130 19131 19132 19133 19134 19135 19136 19137 19138 19139 19140 19141 19142 19143 19144 19145 19146 19147 19148 19149 19150 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 19127 def model_get_lookup_name(building_type) lookup_name = building_type case building_type when 'SmallOffice' lookup_name = 'Office' when 'MediumOffice' lookup_name = 'Office' when 'LargeOffice' lookup_name = 'Office' when 'SmallOfficeDetailed' lookup_name = 'Office' when 'MediumOfficeDetailed' lookup_name = 'Office' when 'LargeOfficeDetailed' lookup_name = 'Office' when 'RetailStandalone' lookup_name = 'Retail' when 'RetailStripmall' lookup_name = 'StripMall' when 'Office' lookup_name = 'Office' end return lookup_name end |
#model_modify_oa_controller(model) ⇒ Object
Does nothing unless implmented by the specific standard
19111 19112 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 19111 def model_modify_oa_controller(model) end |
#model_reset_or_room_vav_minimum_damper(prototype_input, model) ⇒ Object
Does nothing unless implmented by the specific standard
19114 19115 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 19114 def model_reset_or_room_vav_minimum_damper(prototype_input, model) end |
#model_update_exhaust_fan_efficiency(model) ⇒ Object
Does nothing unless implmented by the specific standard
19117 19118 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 19117 def model_update_exhaust_fan_efficiency(model) end |
#model_update_fan_efficiency(model) ⇒ Object
Does nothing unless implmented by the specific standard
19120 19121 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 19120 def model_update_fan_efficiency(model) end |
#set_variables ⇒ Object
This method is used to extend the class with building-type-specific methods, as defined in Prototype.SomeBuildingType.rb. Each building type has its own set of methods that change things which are not common across all prototype buildings, even within a given Standard.
19087 19088 19089 19090 19091 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 19087 def set_variables() # Will be overwritten in class reopen file. # add all building methods for now. self.extend(Outpatient) unless @template == 'NECB 2011' end |