Module: PrototypeBuilding::QuickServiceRestaurant
- Defined in:
- lib/openstudio-standards/prototypes/Prototype.quick_service_restaurant.rb
Class Method Summary collapse
- .add_door_infiltration(template, climate_zone, model) ⇒ Object
-
.add_extra_equip_kitchen(template, model) ⇒ Object
add extra equipment for kitchen.
- .add_zone_mixing(template, model) ⇒ Object
- .adjust_clg_setpoint(template, climate_zone, model) ⇒ Object
- .custom_hvac_tweaks(building_type, template, climate_zone, prototype_input, model) ⇒ Object
- .custom_swh_tweaks(building_type, template, climate_zone, prototype_input, model) ⇒ Object
- .define_hvac_system_map(building_type, template, climate_zone) ⇒ Object
- .define_space_type_map(building_type, template, climate_zone) ⇒ Object
-
.reset_kitchen_oa(template, model) ⇒ Object
In order to provide sufficient OSA to replace exhaust flow through kitchen hoods (3,300 cfm), modeled OSA to kitchen is different from OSA determined based on ASHRAE 62.1.
- .update_exhaust_fan_efficiency(template, model) ⇒ Object
- .update_sizing_zone(template, model) ⇒ Object
- .update_waterheater_loss_coefficient(template, model) ⇒ Object
Class Method Details
.add_door_infiltration(template, climate_zone, model) ⇒ Object
334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 |
# File 'lib/openstudio-standards/prototypes/Prototype.quick_service_restaurant.rb', line 334 def self.add_door_infiltration(template, climate_zone, model) # add extra infiltration for dining room door and attic (there is no attic in 'DOE Ref Pre-1980') unless template == 'DOE Ref 1980-2004' || template == 'DOE Ref Pre-1980' dining_space = model.getSpaceByName('Dining').get attic_space = model.getSpaceByName('Attic').get infiltration_diningdoor = OpenStudio::Model::SpaceInfiltrationDesignFlowRate.new(model) infiltration_attic = OpenStudio::Model::SpaceInfiltrationDesignFlowRate.new(model) infiltration_diningdoor.setName('Dining door Infiltration') infiltration_per_zone_diningdoor = 0 infiltration_per_zone_attic = 0.0729 if template == '90.1-2004' infiltration_per_zone_diningdoor = 0.902834611 infiltration_diningdoor.setSchedule(model.add_schedule('RestaurantFastFood DOOR_INFIL_SCH')) elsif template == '90.1-2007' case climate_zone when 'ASHRAE 169-2006-1A', 'ASHRAE 169-2006-2A', 'ASHRAE 169-2006-2B', 'ASHRAE 169-2006-3A', 'ASHRAE 169-2006-3B', 'ASHRAE 169-2006-3C', 'ASHRAE 169-2006-4A', 'ASHRAE 169-2006-4B', 'ASHRAE 169-2006-4C' infiltration_per_zone_diningdoor = 0.902834611 infiltration_diningdoor.setSchedule(model.add_schedule('RestaurantFastFood DOOR_INFIL_SCH')) else infiltration_per_zone_diningdoor = 0.583798439 infiltration_diningdoor.setSchedule(model.add_schedule('RestaurantFastFood VESTIBULE_DOOR_INFIL_SCH')) end elsif template == '90.1-2010' || template == '90.1-2013' case climate_zone when 'ASHRAE 169-2006-1A', 'ASHRAE 169-2006-2A', 'ASHRAE 169-2006-2B', 'ASHRAE 169-2006-3A', 'ASHRAE 169-2006-3B', 'ASHRAE 169-2006-3C' infiltration_per_zone_diningdoor = 0.902834611 infiltration_diningdoor.setSchedule(model.add_schedule('RestaurantFastFood DOOR_INFIL_SCH')) else infiltration_per_zone_diningdoor = 0.583798439 infiltration_diningdoor.setSchedule(model.add_schedule('RestaurantFastFood VESTIBULE_DOOR_INFIL_SCH')) end end infiltration_diningdoor.setDesignFlowRate(infiltration_per_zone_diningdoor) infiltration_diningdoor.setSpace(dining_space) infiltration_attic.setDesignFlowRate(infiltration_per_zone_attic) infiltration_attic.setSchedule(model.add_schedule('Always On')) infiltration_attic.setSpace(attic_space) end end |
.add_extra_equip_kitchen(template, model) ⇒ Object
add extra equipment for kitchen
376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 |
# File 'lib/openstudio-standards/prototypes/Prototype.quick_service_restaurant.rb', line 376 def self.add_extra_equip_kitchen(template, model) kitchen_space = model.getSpaceByName('Kitchen') kitchen_space = kitchen_space.get kitchen_space_type = kitchen_space.spaceType.get elec_equip_def1 = OpenStudio::Model::ElectricEquipmentDefinition.new(model) elec_equip_def2 = OpenStudio::Model::ElectricEquipmentDefinition.new(model) elec_equip_def1.setName('Kitchen Electric Equipment Definition1') elec_equip_def2.setName('Kitchen Electric Equipment Definition2') case template when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013' elec_equip_def1.setFractionLatent(0) elec_equip_def1.setFractionRadiant(0.25) elec_equip_def1.setFractionLost(0) elec_equip_def2.setFractionLatent(0) elec_equip_def2.setFractionRadiant(0.25) elec_equip_def2.setFractionLost(0) if template == '90.1-2013' elec_equip_def1.setDesignLevel(457.5) elec_equip_def2.setDesignLevel(570) else elec_equip_def1.setDesignLevel(515.917) elec_equip_def2.setDesignLevel(851.67) end # Create the electric equipment instance and hook it up to the space type elec_equip1 = OpenStudio::Model::ElectricEquipment.new(elec_equip_def1) elec_equip2 = OpenStudio::Model::ElectricEquipment.new(elec_equip_def2) elec_equip1.setName('Kitchen_Reach-in-Freezer') elec_equip2.setName('Kitchen_Reach-in-Refrigerator') elec_equip1.setSpaceType(kitchen_space_type) elec_equip2.setSpaceType(kitchen_space_type) elec_equip1.setSchedule(model.add_schedule('RestaurantFastFood ALWAYS_ON')) elec_equip2.setSchedule(model.add_schedule('RestaurantFastFood ALWAYS_ON')) when 'DOE Ref Pre-1980', 'DOE Ref 1980-2004' elec_equip_def1.setDesignLevel(577) elec_equip_def1.setFractionLatent(0) elec_equip_def1.setFractionRadiant(0) elec_equip_def1.setFractionLost(1) # Create the electric equipment instance and hook it up to the space type elec_equip1 = OpenStudio::Model::ElectricEquipment.new(elec_equip_def1) elec_equip1.setName('Kitchen_ExhFan_Equip') elec_equip1.setSpaceType(kitchen_space_type) elec_equip1.setSchedule(model.add_schedule('RestaurantFastFood Kitchen_Exhaust_SCH')) end end |
.add_zone_mixing(template, model) ⇒ Object
493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 |
# File 'lib/openstudio-standards/prototypes/Prototype.quick_service_restaurant.rb', line 493 def self.add_zone_mixing(template, model) # add zone_mixing between kitchen and dining space_kitchen = model.getSpaceByName('Kitchen').get zone_kitchen = space_kitchen.thermalZone.get space_dining = model.getSpaceByName('Dining').get zone_dining = space_dining.thermalZone.get zone_mixing_kitchen = OpenStudio::Model::ZoneMixing.new(zone_kitchen) zone_mixing_kitchen.setSchedule(model.add_schedule('RestaurantFastFood Hours_of_operation')) case template when 'DOE Ref Pre-1980', 'DOE Ref 1980-2004' zone_mixing_kitchen.setDesignFlowRate(0.834532374) when '90.1-2007', '90.1-2010', '90.1-2013' zone_mixing_kitchen.setDesignFlowRate(0.416067345) when '90.1-2004' zone_mixing_kitchen.setDesignFlowRate(0.826232888) end zone_mixing_kitchen.setSourceZone(zone_dining) zone_mixing_kitchen.setDeltaTemperature(0) end |
.adjust_clg_setpoint(template, climate_zone, model) ⇒ Object
440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 |
# File 'lib/openstudio-standards/prototypes/Prototype.quick_service_restaurant.rb', line 440 def self.adjust_clg_setpoint(template, climate_zone, model) ['Dining', 'Kitchen'].each do |space_name| space_type_name = model.getSpaceByName(space_name).get.spaceType.get.name.get thermostat_name = space_type_name + ' Thermostat' thermostat = model.getThermostatSetpointDualSetpointByName(thermostat_name).get case template when '90.1-2004', '90.1-2007', '90.1-2010' if climate_zone == 'ASHRAE 169-2006-2B' || climate_zone == 'ASHRAE 169-2006-1B' || climate_zone == 'ASHRAE 169-2006-3B' case space_name when 'Dining' thermostat.setCoolingSetpointTemperatureSchedule(model.add_schedule('RestaurantFastFood CLGSETP_SCH_NO_OPTIMUM')) when 'Kitchen' thermostat.setCoolingSetpointTemperatureSchedule(model.add_schedule('RestaurantFastFood CLGSETP_KITCHEN_SCH_NO_OPTIMUM')) end end end end end |
.custom_hvac_tweaks(building_type, template, climate_zone, prototype_input, model) ⇒ Object
313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 |
# File 'lib/openstudio-standards/prototypes/Prototype.quick_service_restaurant.rb', line 313 def self.custom_hvac_tweaks(building_type, template, climate_zone, prototype_input, model) OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Started building type specific adjustments') # add extra equipment for kitchen PrototypeBuilding::QuickServiceRestaurant.add_extra_equip_kitchen(template, model) # add extra infiltration for dining room door and attic PrototypeBuilding::QuickServiceRestaurant.add_door_infiltration(template, climate_zone, model) # add zone_mixing between kitchen and dining PrototypeBuilding::QuickServiceRestaurant.add_zone_mixing(template, model) # Update Sizing Zone PrototypeBuilding::QuickServiceRestaurant.update_sizing_zone(template, model) # adjust the cooling setpoint PrototypeBuilding::QuickServiceRestaurant.adjust_clg_setpoint(template, climate_zone, model) # reset the design OA of kitchen PrototypeBuilding::QuickServiceRestaurant.reset_kitchen_oa(template, model) OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Finished building type specific adjustments') return true end |
.custom_swh_tweaks(building_type, template, climate_zone, prototype_input, model) ⇒ Object
523 524 525 526 527 |
# File 'lib/openstudio-standards/prototypes/Prototype.quick_service_restaurant.rb', line 523 def self.custom_swh_tweaks(building_type, template, climate_zone, prototype_input, model) PrototypeBuilding::QuickServiceRestaurant.update_waterheater_loss_coefficient(template, model) return true end |
.define_hvac_system_map(building_type, template, climate_zone) ⇒ Object
30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 |
# File 'lib/openstudio-standards/prototypes/Prototype.quick_service_restaurant.rb', line 30 def self.define_hvac_system_map(building_type, template, climate_zone) case template when 'DOE Ref Pre-1980', 'DOE Ref 1980-2004' system_to_space_map = [ { 'type' => 'PSZ-AC', 'space_names' => ['Dining', 'Kitchen'] }, { 'type' => 'Exhaust Fan', 'name' => 'Dining Exhaust Fan', 'availability_sch_name' => 'RestaurantFastFood HVACOperationSchd', 'flow_rate' => 0.834532374, 'flow_fraction_schedule_name' => nil, 'balanced_exhaust_fraction_schedule_name' => nil, 'space_names' => [ 'Dining' ] }, { 'type' => 'Exhaust Fan', 'name' => 'Kitchen Exhaust Fan', 'availability_sch_name' => 'RestaurantFastFood HVACOperationSchd', 'flow_rate' => 0.722467626, 'flow_fraction_schedule_name' => nil, 'balanced_exhaust_fraction_schedule_name' => nil, 'space_names' => [ 'Kitchen' ] }, { 'type' => 'Refrigeration', 'case_type' => 'Walkin Freezer', 'cooling_capacity_per_length' => 688, 'length' => 2.44, 'evaporator_fan_pwr_per_length' => 74, 'lighting_per_length' => 33, 'lighting_sch_name' => 'QuickServiceRestaurant Bldg Light', 'defrost_pwr_per_length' => 1291.7, 'restocking_sch_name' => 'RestaurantFastFood Kitchen_Case:1_WALKINFREEZER_WalkInStockingSched', 'cop' => 1.5, 'cop_f_of_t_curve_name' => 'RACK1_RackCOPfTCurve', 'condenser_fan_pwr' => 330, 'condenser_fan_pwr_curve_name' => 'RACK1_RackCondFanCurve2', 'space_names' => [ 'Kitchen' ] }, { 'type' => 'Refrigeration', 'case_type' => 'Display Case', 'cooling_capacity_per_length' => 734.0, 'length' => 3.05, 'evaporator_fan_pwr_per_length' => 66, 'lighting_per_length' => 33.0, 'lighting_sch_name' => 'QuickServiceRestaurant Bldg Light', 'defrost_pwr_per_length' => 0.0, 'restocking_sch_name' => 'RestaurantFastFood Kitchen_Case:2_SELFCONTAINEDDISPLAYCASE_CaseStockingSched', 'cop' => 3.0, 'cop_f_of_t_curve_name' => 'RACK2_RackCOPfTCurve', 'condenser_fan_pwr' => 330, 'condenser_fan_pwr_curve_name' => nil, 'space_names' => [ 'Kitchen' ] } ] when '90.1-2004' system_to_space_map = [ { 'type' => 'PSZ-AC', 'space_names' => ['Dining', 'Kitchen'] }, { 'type' => 'Exhaust Fan', 'name' => 'Kitchen Exhaust Fan', 'availability_sch_name' => 'RestaurantFastFood Hours_of_operation', 'flow_rate' => 1.557427, 'flow_fraction_schedule_name' => nil, 'balanced_exhaust_fraction_schedule_name' => 'RestaurantFastFood Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule_2004', 'space_names' => [ 'Kitchen' ] }, { 'type' => 'Exhaust Fan', 'name' => 'Dining Exhaust Fan', 'availability_sch_name' => 'RestaurantFastFood Hours_of_operation', 'flow_rate' => 0.826233, 'flow_fraction_schedule_name' => nil, 'balanced_exhaust_fraction_schedule_name' => nil, 'space_names' => [ 'Dining' ] }, { 'type' => 'Refrigeration', 'case_type' => 'Walkin Freezer', 'cooling_capacity_per_length' => 688, 'length' => 2.44, 'evaporator_fan_pwr_per_length' => 74, 'lighting_per_length' => 33, 'lighting_sch_name' => 'RestaurantFastFood BLDG_LIGHT_DINING_SCH_2004_2007', 'defrost_pwr_per_length' => 1291.7, 'restocking_sch_name' => 'RestaurantFastFood Kitchen_Case:1_WALKINFREEZER_WalkInStockingSched', 'cop' => 1.5, 'cop_f_of_t_curve_name' => 'RACK1_RackCOPfTCurve', 'condenser_fan_pwr' => 330, 'condenser_fan_pwr_curve_name' => 'RACK1_RackCondFanCurve2', 'space_names' => [ 'Kitchen' ] }, { 'type' => 'Refrigeration', 'case_type' => 'Display Case', 'cooling_capacity_per_length' => 734.0, 'length' => 3.05, 'evaporator_fan_pwr_per_length' => 66, 'lighting_per_length' => 33.0, 'lighting_sch_name' => 'RestaurantFastFood BLDG_LIGHT_DINING_SCH_2004_2007', 'defrost_pwr_per_length' => 0.0, 'restocking_sch_name' => 'RestaurantFastFood Kitchen_Case:2_SELFCONTAINEDDISPLAYCASE_CaseStockingSched', 'cop' => 3.0, 'cop_f_of_t_curve_name' => 'RACK2_RackCOPfTCurve', 'condenser_fan_pwr' => 330, 'condenser_fan_pwr_curve_name' => nil, 'space_names' => [ 'Kitchen' ] } ] when '90.1-2007', '90.1-2010' system_to_space_map = [ { 'type' => 'PSZ-AC', 'space_names' => ['Dining', 'Kitchen'] }, { 'type' => 'Exhaust Fan', 'name' => 'Kitchen Exhaust Fan', 'availability_sch_name' => 'RestaurantFastFood Hours_of_operation', 'flow_rate' => 1.557427, 'flow_fraction_schedule_name' => nil, 'balanced_exhaust_fraction_schedule_name' => 'RestaurantFastFood Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule_2007_2010_2013', 'space_names' => [ 'Kitchen' ] }, { 'type' => 'Exhaust Fan', 'name' => 'Dining Exhaust Fan', 'availability_sch_name' => 'RestaurantFastFood Hours_of_operation', 'flow_rate' => 0.416, 'flow_fraction_schedule_name' => nil, 'balanced_exhaust_fraction_schedule_name' => nil, 'space_names' => [ 'Dining' ] }, { 'type' => 'Refrigeration', 'case_type' => 'Walkin Freezer', 'cooling_capacity_per_length' => 688, 'length' => 2.44, 'evaporator_fan_pwr_per_length' => 74, 'lighting_per_length' => 33, 'lighting_sch_name' => 'RestaurantFastFood BLDG_LIGHT_DINING_SCH_2004_2007', 'defrost_pwr_per_length' => 1291.7, 'restocking_sch_name' => 'RestaurantFastFood Kitchen_Case:1_WALKINFREEZER_WalkInStockingSched', 'cop' => 1.5, 'cop_f_of_t_curve_name' => 'RACK1_RackCOPfTCurve', 'condenser_fan_pwr' => 330, 'condenser_fan_pwr_curve_name' => 'RACK1_RackCondFanCurve2', 'space_names' => [ 'Kitchen' ] }, { 'type' => 'Refrigeration', 'case_type' => 'Display Case', 'cooling_capacity_per_length' => 734.0, 'length' => 3.05, 'evaporator_fan_pwr_per_length' => 66, 'lighting_per_length' => 33.0, 'lighting_sch_name' => 'RestaurantFastFood BLDG_LIGHT_DINING_SCH_2004_2007', 'defrost_pwr_per_length' => 0.0, 'restocking_sch_name' => 'RestaurantFastFood Kitchen_Case:2_SELFCONTAINEDDISPLAYCASE_CaseStockingSched', 'cop' => 3.0, 'cop_f_of_t_curve_name' => 'RACK2_RackCOPfTCurve', 'condenser_fan_pwr' => 330, 'condenser_fan_pwr_curve_name' => nil, 'space_names' => [ 'Kitchen' ] } ] when '90.1-2013' system_to_space_map = [ { 'type' => 'PSZ-AC', 'space_names' => ['Dining', 'Kitchen'] }, { 'type' => 'Exhaust Fan', 'name' => 'Kitchen Exhaust Fan', 'availability_sch_name' => 'RestaurantFastFood Hours_of_operation', 'flow_rate' => 1.557427, 'flow_fraction_schedule_name' => nil, 'balanced_exhaust_fraction_schedule_name' => 'RestaurantFastFood Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule_2007_2010_2013', 'space_names' => [ 'Kitchen' ] }, { 'type' => 'Exhaust Fan', 'name' => 'Dining Exhaust Fan', 'availability_sch_name' => 'RestaurantFastFood Hours_of_operation', 'flow_rate' => 0.416, 'flow_fraction_schedule_name' => nil, 'balanced_exhaust_fraction_schedule_name' => nil, 'space_names' => [ 'Dining' ] }, { 'type' => 'Refrigeration', 'case_type' => 'Walkin Freezer', 'cooling_capacity_per_length' => 688, 'length' => 2.44, 'evaporator_fan_pwr_per_length' => 21.143, 'lighting_per_length' => 33, 'lighting_sch_name' => 'RestaurantFastFood walkin_occ_lght_SCH', 'defrost_pwr_per_length' => 1291.7, 'restocking_sch_name' => 'RestaurantFastFood Kitchen_Case:1_WALKINFREEZER_WalkInStockingSched', 'cop' => 1.5, 'cop_f_of_t_curve_name' => 'RACK1_RackCOPfTCurve', 'condenser_fan_pwr' => 330, 'condenser_fan_pwr_curve_name' => 'RACK1_RackCondFanCurve2', 'space_names' => [ 'Kitchen' ] }, { 'type' => 'Refrigeration', 'case_type' => 'Display Case', 'cooling_capacity_per_length' => 734.0, 'length' => 3.05, 'evaporator_fan_pwr_per_length' => 18.857, 'lighting_per_length' => 33.0, 'lighting_sch_name' => 'RestaurantFastFood walkin_occ_lght_SCH', 'defrost_pwr_per_length' => 0.0, 'restocking_sch_name' => 'RestaurantFastFood Kitchen_Case:2_SELFCONTAINEDDISPLAYCASE_CaseStockingSched', 'cop' => 3.0, 'cop_f_of_t_curve_name' => 'RACK2_RackCOPfTCurve', 'condenser_fan_pwr' => 330, 'condenser_fan_pwr_curve_name' => nil, 'space_names' => [ 'Kitchen' ] } ] end return system_to_space_map end |
.define_space_type_map(building_type, template, climate_zone) ⇒ Object
5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 |
# File 'lib/openstudio-standards/prototypes/Prototype.quick_service_restaurant.rb', line 5 def self.define_space_type_map(building_type, template, climate_zone) space_type_map = nil case template when 'DOE Ref Pre-1980' space_type_map = { 'Dining' => ['Dining'], 'Kitchen' => ['Kitchen'] } when 'DOE Ref 1980-2004', '90.1-2010', '90.1-2007', '90.1-2004', '90.1-2013' space_type_map = { 'Dining' => ['Dining'], 'Kitchen' => ['Kitchen'], 'Attic' => ['attic'] } when 'NECB 2011' # dom = B space_type_map = { '- undefined -' => ['attic'], 'Dining - bar lounge/leisure' => ['Dining'], 'Food preparation' => ['Kitchen'] } end return space_type_map end |
.reset_kitchen_oa(template, model) ⇒ Object
In order to provide sufficient OSA to replace exhaust flow through kitchen hoods (3,300 cfm), modeled OSA to kitchen is different from OSA determined based on ASHRAE 62.1. It takes into account the available OSA in dining as transfer air.
462 463 464 465 466 467 468 469 470 471 472 473 |
# File 'lib/openstudio-standards/prototypes/Prototype.quick_service_restaurant.rb', line 462 def self.reset_kitchen_oa(template, model) space_kitchen = model.getSpaceByName('Kitchen').get ventilation = space_kitchen.designSpecificationOutdoorAir.get ventilation.setOutdoorAirFlowperPerson(0) ventilation.setOutdoorAirFlowperFloorArea(0) case template when '90.1-2007', '90.1-2010', '90.1-2013' ventilation.setOutdoorAirFlowRate(1.14135966) when '90.1-2004', 'DOE Ref Pre-1980', 'DOE Ref 1980-2004' ventilation.setOutdoorAirFlowRate(0.7312) end end |
.update_exhaust_fan_efficiency(template, model) ⇒ Object
475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 |
# File 'lib/openstudio-standards/prototypes/Prototype.quick_service_restaurant.rb', line 475 def self.update_exhaust_fan_efficiency(template, model) case template when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013' model.getFanZoneExhausts.sort.each do |exhaust_fan| fan_name = exhaust_fan.name.to_s if fan_name.include? 'Dining' exhaust_fan.setFanEfficiency(1) exhaust_fan.setPressureRise(0) end end when 'DOE Ref Pre-1980', 'DOE Ref 1980-2004' model.getFanZoneExhausts.sort.each do |exhaust_fan| exhaust_fan.setFanEfficiency(1) exhaust_fan.setPressureRise(0.000001) end end end |
.update_sizing_zone(template, model) ⇒ Object
421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 |
# File 'lib/openstudio-standards/prototypes/Prototype.quick_service_restaurant.rb', line 421 def self.update_sizing_zone(template, model) case template when '90.1-2007', '90.1-2010', '90.1-2013' zone_sizing = model.getSpaceByName('Dining').get.thermalZone.get.sizingZone zone_sizing.setCoolingDesignAirFlowMethod('DesignDayWithLimit') zone_sizing.setCoolingMinimumAirFlowperZoneFloorArea(0.003581176) zone_sizing = model.getSpaceByName('Kitchen').get.thermalZone.get.sizingZone zone_sizing.setCoolingDesignAirFlowMethod('DesignDayWithLimit') zone_sizing.setCoolingMinimumAirFlowperZoneFloorArea(0) when '90.1-2004' zone_sizing = model.getSpaceByName('Dining').get.thermalZone.get.sizingZone zone_sizing.setCoolingDesignAirFlowMethod('DesignDayWithLimit') zone_sizing.setCoolingMinimumAirFlowperZoneFloorArea(0.007111554) zone_sizing = model.getSpaceByName('Kitchen').get.thermalZone.get.sizingZone zone_sizing.setCoolingDesignAirFlowMethod('DesignDayWithLimit') zone_sizing.setCoolingMinimumAirFlowperZoneFloorArea(0) end end |
.update_waterheater_loss_coefficient(template, model) ⇒ Object
513 514 515 516 517 518 519 520 521 |
# File 'lib/openstudio-standards/prototypes/Prototype.quick_service_restaurant.rb', line 513 def self.update_waterheater_loss_coefficient(template, model) case template when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', 'NECB 2011' model.getWaterHeaterMixeds.sort.each do |water_heater| water_heater.setOffCycleLossCoefficienttoAmbientTemperature(7.561562668) water_heater.setOnCycleLossCoefficienttoAmbientTemperature(7.561562668) end end end |