Module: BTAP::Resources::HVAC::ZoneEquipment
- Defined in:
- lib/openstudio-standards/btap/hvac.rb
Defined Under Namespace
Classes: ZoneEquipmentTests
Class Method Summary
collapse
-
.add_baseboard_convective_electric(model, zone) ⇒ Object
-
.add_baseboard_convective_water(model, zone, hot_water_loop) ⇒ Object
-
.add_four_pipe_fan_coil(model, zone, hot_water_loop, cold_water_loop) ⇒ Object
-
.add_ideal_air_loads(model, zone) ⇒ Object
-
.add_low_temp_radiant_constant_flow(model, zone, hot_water_loop, cold_water_loop) ⇒ Object
-
.add_low_temp_radiant_electric(model, zone) ⇒ Object
-
.add_low_temp_radiant_var_flow(model, zone, hot_water_loop, cold_water_loop) ⇒ Object
-
.add_ptac(model, zone, hot_water_loop) ⇒ Object
-
.add_pthp(model, zone) ⇒ Object
-
.add_unit_heater(model, zone, heat_source = "electric", fan_source = "CV", hot_water_loop = nil) ⇒ Object
-
.add_water_to_air_heat_pump(model, zone, backup_source = "naturalgas", hp_hot_water_loop = nil, hp_cold_water_loop = nil, hot_water_backup_loop = nil) ⇒ Object
-
.add_zone_baseboard_convective_water(model, avail_sched, baseboard_coil) ⇒ Object
-
.add_zoneHVAC_fpfc(model, avail_sched, supply_fan, cool_coil, htg_coil) ⇒ Object
Class Method Details
.add_baseboard_convective_electric(model, zone) ⇒ Object
751
752
753
754
755
756
|
# File 'lib/openstudio-standards/btap/hvac.rb', line 751
def self.add_baseboard_convective_electric(model,zone)
equipment = BTAP::OpenStudioLibrary.instance.library.getZoneHVACBaseboardConvectiveElectricByName("Zone HVAC Baseboard Convective Electric 1").get
equipment = equipment.clone(model).to_ZoneHVACBaseboardConvectiveElectric.get
equipment.addToThermalZone(zone)
return equipment
end
|
.add_baseboard_convective_water(model, zone, hot_water_loop) ⇒ Object
739
740
741
742
743
744
745
|
# File 'lib/openstudio-standards/btap/hvac.rb', line 739
def self.add_baseboard_convective_water(model,zone,hot_water_loop)
equipment = BTAP::OpenStudioLibrary.instance.library.getZoneHVACBaseboardConvectiveWaterByName("Convective Baseboard Water").get
equipment = equipment.clone(model).to_ZoneHVACBaseboardConvectiveWater.get
equipment.addToThermalZone(zone)
hot_water_loop.addDemandBranchForComponent(equipment.heatingCoil()) unless hot_water_loop.to_PlantLoop.empty?
return equipment
end
|
.add_four_pipe_fan_coil(model, zone, hot_water_loop, cold_water_loop) ⇒ Object
711
712
713
714
715
716
717
718
|
# File 'lib/openstudio-standards/btap/hvac.rb', line 711
def self.add_four_pipe_fan_coil(model,zone,hot_water_loop,cold_water_loop)
equipment = BTAP::OpenStudioLibrary.instance.library.getZoneHVACFourPipeFanCoilByName("Zone HVAC Four Pipe Fan Coil 1").get
equipment = equipment.clone(model).to_ZoneHVACFourPipeFanCoil.get
equipment.addToThermalZone(zone)
hot_water_loop.addDemandBranchForComponent(equipment.heatingCoil()) unless hot_water_loop.to_PlantLoop.empty?
cold_water_loop.addDemandBranchForComponent(equipment.coolingCoil()) unless cold_water_loop.to_PlantLoop.empty?
return equipment
end
|
.add_ideal_air_loads(model, zone) ⇒ Object
680
681
682
|
# File 'lib/openstudio-standards/btap/hvac.rb', line 680
def self.add_ideal_air_loads(model,zone)
zone.setUseIdealAirLoads(true)
end
|
.add_low_temp_radiant_constant_flow(model, zone, hot_water_loop, cold_water_loop) ⇒ Object
702
703
704
705
706
707
708
709
|
# File 'lib/openstudio-standards/btap/hvac.rb', line 702
def self.add_low_temp_radiant_constant_flow(model,zone,hot_water_loop,cold_water_loop)
equipment = BTAP::OpenStudioLibrary.instance.library.getZoneHVACLowTempRadiantConstFlowByName("Low Temp Radiant Const Flow").get
equipment = equipment.clone(model).to_ZoneHVACLowTempRadiantConstFlow.get
equipment.addToThermalZone(zone)
hot_water_loop.addDemandBranchForComponent(equipment.heatingCoil()) unless hot_water_loop.to_PlantLoop.empty?
cold_water_loop.addDemandBranchForComponent(equipment.coolingCoil()) unless cold_water_loop.to_PlantLoop.empty?
return equipment
end
|
.add_low_temp_radiant_electric(model, zone) ⇒ Object
686
687
688
689
690
691
|
# File 'lib/openstudio-standards/btap/hvac.rb', line 686
def self.add_low_temp_radiant_electric(model,zone)
equipment = BTAP::OpenStudioLibrary.instance.library.getZoneHVACLowTemperatureRadiantElectricByName("Low Temperature Radiant Electric").get
equipment = equipment.clone(model).to_ZoneHVACLowTemperatureRadiantElectric.get
equipment.addToThermalZone(zone)
return equipment
end
|
.add_low_temp_radiant_var_flow(model, zone, hot_water_loop, cold_water_loop) ⇒ Object
693
694
695
696
697
698
699
700
|
# File 'lib/openstudio-standards/btap/hvac.rb', line 693
def self.add_low_temp_radiant_var_flow(model,zone,hot_water_loop,cold_water_loop)
equipment = BTAP::OpenStudioLibrary.instance.library.getZoneHVACLowTempRadiantVarFlowByName("Low Temp Radiant Var Flow").get
equipment = equipment.clone(model).to_ZoneHVACLowTempRadiantVarFlow.get
equipment.addToThermalZone(zone)
hot_water_loop.addDemandBranchForComponent(equipment.heatingCoil()) unless hot_water_loop.to_PlantLoop.empty?
cold_water_loop.addDemandBranchForComponent(equipment.coolingCoil()) unless cold_water_loop.to_PlantLoop.empty?
return equipment
end
|
.add_ptac(model, zone, hot_water_loop) ⇒ Object
731
732
733
734
735
736
737
|
# File 'lib/openstudio-standards/btap/hvac.rb', line 731
def self.add_ptac(model,zone,hot_water_loop)
equipment = BTAP::OpenStudioLibrary.instance.library.getZoneHVACPackagedTerminalAirConditionerByName("OS:ZoneHVAC:PackagedTerminalAirConditioner 1").get
equipment = equipment.clone(model).to_ZoneHVACPackagedTerminalAirConditioner.get
equipment.addToThermalZone(zone)
hot_water_loop.addDemandBranchForComponent(equipment.heatingCoil()) unless hot_water_loop.to_PlantLoop.empty?
return equipment
end
|
.add_pthp(model, zone) ⇒ Object
724
725
726
727
728
729
|
# File 'lib/openstudio-standards/btap/hvac.rb', line 724
def self.add_pthp(model,zone)
equipment = BTAP::OpenStudioLibrary.instance.library.getZoneHVACPackagedTerminalHeatPumpByName("OS:ZoneHVAC:PackagedTerminalHeatPump 1").get
equipment = equipment.clone(model).to_ZoneHVACPackagedTerminalHeatPump.get
equipment.addToThermalZone(zone)
return equipment
end
|
.add_unit_heater(model, zone, heat_source = "electric", fan_source = "CV", hot_water_loop = nil) ⇒ Object
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
|
# File 'lib/openstudio-standards/btap/hvac.rb', line 784
def self.add_unit_heater(model,zone,heat_source="electric",fan_source = "CV",hot_water_loop = nil)
heat_source = heat_source.downcase
fan_source = fan_source.downcase
valid_heat_sources = ["electric","naturalgas","hotwater"]
raise("Heat source #{heat_source} is invalid. please use #{valid_heat_sources}. ") unless valid_heat_sources.include?(heat_source)
valid_fan_sources = ["vav","cv"]
raise("Fan source #{fan_source} is invalid. please use a valid fan source name...#{valid_fan_sources}. ") unless valid_fan_sources.include?(fan_source)
lib_name = ""
if heat_source.downcase == "electric"
if fan_source == "cv"
lib_name = "Unit Heater CV - Electric"
elsif fan_source == "vav"
lib_name = "Unit Heater VAV - Electric"
end
elsif heat_source.downcase == "naturalgas"
if fan_source == "cv"
lib_name = "Unit Heater CV - Gas"
elsif fan_source == "vav"
lib_name = "Unit Heater VAV - Gas"
end
elsif heat_source.downcase == "hotwater"
if fan_source == "cv"
lib_name = "Unit Heater CV - Hot Water"
elsif fan_source == "vav"
lib_name = "Unit Heater VAV - Hot Water"
end
end
unit_heater = BTAP::OpenStudioLibrary.instance.library.getZoneHVACUnitHeaterByName(lib_name).get
new_unit_heater = unit_heater.clone(model).to_ZoneHVACUnitHeater.get
new_unit_heater.addToThermalZone(zone);
hot_water_loop.addDemandBranchForComponent(new_unit_heater.heatingCoil()) unless hot_water_loop.nil? or hot_water_loop.to_PlantLoop.empty?
return unit_heater
end
|
.add_water_to_air_heat_pump(model, zone, backup_source = "naturalgas", hp_hot_water_loop = nil, hp_cold_water_loop = nil, hot_water_backup_loop = nil) ⇒ Object
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
|
# File 'lib/openstudio-standards/btap/hvac.rb', line 768
def self.add_water_to_air_heat_pump(model,zone,backup_source = "naturalgas",hp_hot_water_loop = nil,hp_cold_water_loop = nil,hot_water_backup_loop = nil)
backup_source = backup_source.downcase
valid_heat_sources = ["electric","naturalgas","hotwater"]
raise("Backup Heat Source #{backup_source} is invalid. please use #{valid_heat_sources}. ") unless valid_heat_sources.include?(backup_source)
lib_name = ""
lib_name = "Water To Air Heat Pump w Gas Supplemental Coil" if backup_source == "naturalgas"
lib_name = "Water to Air Heat Pump w Hot Water Supplemental Coil" if backup_source == "hotwater"
lib_name = "Water To Air HP w Elec Supplemental Coil" if backup_source == "electric"
equipment = BTAP::OpenStudioLibrary.instance.library.getZoneHVACWaterToAirHeatPumpByName(lib_name).get
equipment = equipment.clone(model).to_ZoneHVACWaterToAirHeatPump.get
equipment.addToThermalZone(zone)
hp_hot_water_loop.addDemandBranchForComponent(equipment.heatingCoil()) unless hp_hot_water_loop.nil? or hp_hot_water_loop.to_PlantLoop.empty?
hp_cold_water_loop.addDemandBranchForComponent(equipment.coolingCoil()) unless hp_hot_water_loop.nil? or hp_cold_water_loop.to_PlantLoop.empty?
hot_water_backup_loop.addDemandBranchForComponent(equipment.supplementalHeatingCoil()) unless hot_water_backup_loop.nil? or hot_water_backup_loop.to_PlantLoop.empty?
end
|
.add_zone_baseboard_convective_water(model, avail_sched, baseboard_coil) ⇒ Object
747
748
749
|
# File 'lib/openstudio-standards/btap/hvac.rb', line 747
def self.add_zone_baseboard_convective_water(model,avail_sched,baseboard_coil)
return OpenStudio::Model::ZoneHVACBaseboardConvectiveWater.new(model,avail_sched,baseboard_coil);
end
|
.add_zoneHVAC_fpfc(model, avail_sched, supply_fan, cool_coil, htg_coil) ⇒ Object
720
721
722
|
# File 'lib/openstudio-standards/btap/hvac.rb', line 720
def self.add_zoneHVAC_fpfc(model,avail_sched,supply_fan,cool_coil,htg_coil)
return OpenStudio::Model::ZoneHVACFourPipeFanCoil.new(model,avail_sched,supply_fan,cool_coil,htg_coil)
end
|