Class: OpenStudio::Model::RefrigerationCase
Class Method Summary
collapse
Instance Method Summary
collapse
#allowableChildTypes, #children
Methods inherited from ModelObject
#EqualEqual, #LessThan, #NotEqual, #__str__, #clone, #connectedObject, #connectedObjectPort, #createComponent, #getData, #getScheduleTypeKeys, #iddObjectType, #lifeCycleCosts, #model, #outputVariableNames, #outputVariables, #parent, #removeLifeCycleCosts, #resources, #setParent, #toIdfObject
#LessThan, #__str__, #canBeSource, #canBeTarget, #getSourceIndices, #getSources, #getTarget, #idfObject, #initialized, #isSource, #isTarget, #numSources, #objectListFieldsEqual, #objectListFieldsNonConflicting, #remove, #setPointer, #sources, #targets, #workspace
Class Method Details
.antiSweatHeaterControlTypeValues ⇒ StringVector
187
188
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 187
def self.antiSweatHeaterControlTypeValues
end
|
.caseDefrostTypeValues ⇒ StringVector
190
191
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 190
def self.caseDefrostTypeValues
end
|
.defrostEnergyCorrectionCurveTypeValues ⇒ StringVector
193
194
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 193
def self.defrostEnergyCorrectionCurveTypeValues
end
|
181
182
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 181
def self.iddObjectType
end
|
.latentCaseCreditCurveTypeValues ⇒ StringVector
184
185
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 184
def self.latentCaseCreditCurveTypeValues
end
|
.new(model, schedule) ⇒ Object
5
6
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 5
def self.new(model, schedule)
end
|
.unitTypeValues ⇒ StringVector
196
197
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 196
def self.unitTypeValues
end
|
Instance Method Details
#addToSystem(sWIGTYPE_p_RefrigerationSystem) ⇒ Boolean
176
177
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 176
def addToSystem(sWIGTYPE_p_RefrigerationSystem)
end
|
#antiSweatHeaterControlType ⇒ String
298
299
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 298
def antiSweatHeaterControlType
end
|
199
200
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 199
def availabilitySchedule
end
|
#averageRefrigerantChargeInventory ⇒ Double
364
365
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 364
def averageRefrigerantChargeInventory
end
|
#caseAntiSweatHeaterPowerperDoor ⇒ OptionalDouble
388
389
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 388
def caseAntiSweatHeaterPowerperDoor
end
|
#caseAntiSweatHeaterPowerperUnitLength ⇒ Double
286
287
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 286
def caseAntiSweatHeaterPowerperUnitLength
end
|
358
359
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 358
def caseCreditFractionSchedule
end
|
337
338
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 337
def caseDefrostDripDownSchedule
end
|
394
395
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 394
def caseDefrostPowerperDoor
end
|
#caseDefrostPowerperUnitLength ⇒ Double
322
323
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 322
def caseDefrostPowerperUnitLength
end
|
334
335
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 334
def caseDefrostSchedule
end
|
#caseDefrostType ⇒ String
328
329
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 328
def caseDefrostType
end
|
#caseHeight ⇒ Double
310
311
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 310
def caseHeight
end
|
#caseLength ⇒ Double
235
236
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 235
def caseLength
end
|
277
278
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 277
def caseLightingSchedule
end
|
#caseOperatingTemperature ⇒ Double
241
242
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 241
def caseOperatingTemperature
end
|
409
410
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 409
def defrost1StartTime
end
|
412
413
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 412
def defrost2StartTime
end
|
415
416
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 415
def defrost3StartTime
end
|
418
419
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 418
def defrost4StartTime
end
|
421
422
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 421
def defrost5StartTime
end
|
424
425
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 424
def defrost6StartTime
end
|
427
428
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 427
def defrost7StartTime
end
|
430
431
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 430
def defrost8StartTime
end
|
346
347
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 346
def defrostEnergyCorrectionCurve
end
|
#defrostEnergyCorrectionCurveType ⇒ String
340
341
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 340
def defrostEnergyCorrectionCurveType
end
|
#designEvaporatorTemperatureorBrineInletTemperature ⇒ OptionalDouble
361
362
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 361
def designEvaporatorTemperatureorBrineInletTemperature
end
|
406
407
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 406
def dripDownTime
end
|
#durationofDefrostCycle ⇒ OptionalInt
403
404
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 403
def durationofDefrostCycle
end
|
#fractionofAntiSweatHeaterEnergytoCase ⇒ Double
316
317
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 316
def fractionofAntiSweatHeaterEnergytoCase
end
|
#fractionofLightingEnergytoCase ⇒ Double
280
281
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 280
def fractionofLightingEnergytoCase
end
|
#humidityatZeroAntiSweatHeaterEnergy ⇒ Double
304
305
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 304
def humidityatZeroAntiSweatHeaterEnergy
end
|
#installedCaseLightingPowerperDoor ⇒ OptionalDouble
385
386
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 385
def installedCaseLightingPowerperDoor
end
|
#installedCaseLightingPowerperUnitLength ⇒ OptionalDouble
274
275
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 274
def installedCaseLightingPowerperUnitLength
end
|
#isAntiSweatHeaterControlTypeDefaulted ⇒ Boolean
301
302
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 301
def isAntiSweatHeaterControlTypeDefaulted
end
|
#isAverageRefrigerantChargeInventoryDefaulted ⇒ Boolean
367
368
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 367
def isAverageRefrigerantChargeInventoryDefaulted
end
|
#isCaseAntiSweatHeaterPowerperUnitLengthDefaulted ⇒ Boolean
289
290
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 289
def isCaseAntiSweatHeaterPowerperUnitLengthDefaulted
end
|
#isCaseDefrostPowerperUnitLengthDefaulted ⇒ Boolean
325
326
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 325
def isCaseDefrostPowerperUnitLengthDefaulted
end
|
#isCaseDefrostTypeDefaulted ⇒ Boolean
331
332
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 331
def isCaseDefrostTypeDefaulted
end
|
#isCaseHeightDefaulted ⇒ Boolean
313
314
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 313
def isCaseHeightDefaulted
end
|
#isCaseLengthDefaulted ⇒ Boolean
238
239
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 238
def isCaseLengthDefaulted
end
|
#isCaseOperatingTemperatureDefaulted ⇒ Boolean
244
245
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 244
def isCaseOperatingTemperatureDefaulted
end
|
#isDefrostEnergyCorrectionCurveTypeDefaulted ⇒ Boolean
343
344
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 343
def isDefrostEnergyCorrectionCurveTypeDefaulted
end
|
#isFractionofAntiSweatHeaterEnergytoCaseDefaulted ⇒ Boolean
319
320
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 319
def isFractionofAntiSweatHeaterEnergytoCaseDefaulted
end
|
#isFractionofLightingEnergytoCaseDefaulted ⇒ Boolean
283
284
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 283
def isFractionofLightingEnergytoCaseDefaulted
end
|
#isHumidityatZeroAntiSweatHeaterEnergyDefaulted ⇒ Boolean
307
308
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 307
def isHumidityatZeroAntiSweatHeaterEnergyDefaulted
end
|
#isLatentCaseCreditCurveTypeDefaulted ⇒ Boolean
250
251
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 250
def isLatentCaseCreditCurveTypeDefaulted
end
|
#isMinimumAntiSweatHeaterPowerperUnitLengthDefaulted ⇒ Boolean
295
296
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 295
def isMinimumAntiSweatHeaterPowerperUnitLengthDefaulted
end
|
#isOperatingCaseFanPowerperUnitLengthDefaulted ⇒ Boolean
265
266
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 265
def isOperatingCaseFanPowerperUnitLengthDefaulted
end
|
#isRatedAmbientRelativeHumidityDefaulted ⇒ Boolean
214
215
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 214
def isRatedAmbientRelativeHumidityDefaulted
end
|
#isRatedAmbientTemperatureDefaulted ⇒ Boolean
208
209
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 208
def isRatedAmbientTemperatureDefaulted
end
|
#isRatedLatentHeatRatioDefaulted ⇒ Boolean
226
227
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 226
def isRatedLatentHeatRatioDefaulted
end
|
#isRatedRuntimeFractionDefaulted ⇒ Boolean
232
233
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 232
def isRatedRuntimeFractionDefaulted
end
|
#isRatedTotalCoolingCapacityperUnitLengthDefaulted ⇒ Boolean
220
221
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 220
def isRatedTotalCoolingCapacityperUnitLengthDefaulted
end
|
#isStandardCaseFanPowerperUnitLengthDefaulted ⇒ Boolean
259
260
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 259
def isStandardCaseFanPowerperUnitLengthDefaulted
end
|
#isStandardCaseLightingPowerperUnitLengthDefaulted ⇒ Boolean
271
272
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 271
def isStandardCaseLightingPowerperUnitLengthDefaulted
end
|
#isUnderCaseHVACReturnAirFractionDefaulted ⇒ Boolean
352
353
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 352
def isUnderCaseHVACReturnAirFractionDefaulted
end
|
#isUnitTypeDefaulted ⇒ Boolean
400
401
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 400
def isUnitTypeDefaulted
end
|
#latentCaseCreditCurve ⇒ CurveCubic
253
254
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 253
def latentCaseCreditCurve
end
|
#latentCaseCreditCurveType ⇒ String
247
248
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 247
def latentCaseCreditCurveType
end
|
#minimumAntiSweatHeaterPowerperDoor ⇒ OptionalDouble
391
392
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 391
def minimumAntiSweatHeaterPowerperDoor
end
|
#minimumAntiSweatHeaterPowerperUnitLength ⇒ Double
292
293
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 292
def minimumAntiSweatHeaterPowerperUnitLength
end
|
370
371
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 370
def numberOfDoors
end
|
#operatingCaseFanPowerperDoor ⇒ OptionalDouble
379
380
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 379
def operatingCaseFanPowerperDoor
end
|
#operatingCaseFanPowerperUnitLength ⇒ Double
262
263
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 262
def operatingCaseFanPowerperUnitLength
end
|
#ratedAmbientRelativeHumidity ⇒ Double
211
212
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 211
def ratedAmbientRelativeHumidity
end
|
#ratedAmbientTemperature ⇒ Double
205
206
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 205
def ratedAmbientTemperature
end
|
#ratedLatentHeatRatio ⇒ Double
223
224
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 223
def ratedLatentHeatRatio
end
|
#ratedRuntimeFraction ⇒ Double
229
230
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 229
def ratedRuntimeFraction
end
|
#ratedTotalCoolingCapacityperDoor ⇒ OptionalDouble
373
374
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 373
def ratedTotalCoolingCapacityperDoor
end
|
#ratedTotalCoolingCapacityperUnitLength ⇒ Double
217
218
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 217
def ratedTotalCoolingCapacityperUnitLength
end
|
#refrigeratedCaseRestockingSchedule ⇒ OptionalSchedule
355
356
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 355
def refrigeratedCaseRestockingSchedule
end
|
#removeFromSystem ⇒ Object
178
179
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 178
def removeFromSystem
end
|
#resetAntiSweatHeaterControlType ⇒ Object
529
530
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 529
def resetAntiSweatHeaterControlType
end
|
#resetAvailabilitySchedule ⇒ Object
438
439
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 438
def resetAvailabilitySchedule
end
|
#resetAverageRefrigerantChargeInventory ⇒ Object
73
74
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 73
def resetAverageRefrigerantChargeInventory
end
|
#resetCaseAntiSweatHeaterPowerperDoor ⇒ Object
108
109
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 108
def resetCaseAntiSweatHeaterPowerperDoor
end
|
#resetCaseAntiSweatHeaterPowerperUnitLength ⇒ Object
519
520
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 519
def resetCaseAntiSweatHeaterPowerperUnitLength
end
|
#resetCaseCreditFractionSchedule ⇒ Object
64
65
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 64
def resetCaseCreditFractionSchedule
end
|
#resetCaseDefrostDripDownSchedule ⇒ Object
39
40
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 39
def resetCaseDefrostDripDownSchedule
end
|
#resetCaseDefrostPowerperDoor ⇒ Object
118
119
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 118
def resetCaseDefrostPowerperDoor
end
|
#resetCaseDefrostPowerperUnitLength ⇒ Object
24
25
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 24
def resetCaseDefrostPowerperUnitLength
end
|
#resetCaseDefrostSchedule ⇒ Object
34
35
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 34
def resetCaseDefrostSchedule
end
|
#resetCaseDefrostType ⇒ Object
29
30
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 29
def resetCaseDefrostType
end
|
#resetCaseHeight ⇒ Object
14
15
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 14
def resetCaseHeight
end
|
#resetCaseLength ⇒ Object
473
474
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 473
def resetCaseLength
end
|
#resetCaseLightingSchedule ⇒ Object
509
510
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 509
def resetCaseLightingSchedule
end
|
#resetCaseOperatingTemperature ⇒ Object
478
479
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 478
def resetCaseOperatingTemperature
end
|
#resetDefrost1StartTime ⇒ Object
138
139
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 138
def resetDefrost1StartTime
end
|
#resetDefrost2StartTime ⇒ Object
143
144
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 143
def resetDefrost2StartTime
end
|
#resetDefrost3StartTime ⇒ Object
148
149
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 148
def resetDefrost3StartTime
end
|
#resetDefrost4StartTime ⇒ Object
153
154
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 153
def resetDefrost4StartTime
end
|
#resetDefrost5StartTime ⇒ Object
158
159
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 158
def resetDefrost5StartTime
end
|
#resetDefrost6StartTime ⇒ Object
163
164
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 163
def resetDefrost6StartTime
end
|
#resetDefrost7StartTime ⇒ Object
168
169
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 168
def resetDefrost7StartTime
end
|
#resetDefrost8StartTime ⇒ Object
173
174
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 173
def resetDefrost8StartTime
end
|
#resetDefrostEnergyCorrectionCurve ⇒ Object
49
50
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 49
def resetDefrostEnergyCorrectionCurve
end
|
#resetDefrostEnergyCorrectionCurveType ⇒ Object
44
45
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 44
def resetDefrostEnergyCorrectionCurveType
end
|
#resetDesignEvaporatorTemperatureorBrineInletTemperature ⇒ Object
69
70
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 69
def resetDesignEvaporatorTemperatureorBrineInletTemperature
end
|
#resetDripDownTime ⇒ Object
133
134
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 133
def resetDripDownTime
end
|
#resetDurationofDefrostCycle ⇒ Object
128
129
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 128
def resetDurationofDefrostCycle
end
|
#resetFractionofAntiSweatHeaterEnergytoCase ⇒ Object
19
20
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 19
def resetFractionofAntiSweatHeaterEnergytoCase
end
|
#resetFractionofLightingEnergytoCase ⇒ Object
514
515
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 514
def resetFractionofLightingEnergytoCase
end
|
#resetHumidityatZeroAntiSweatHeaterEnergy ⇒ Object
9
10
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 9
def resetHumidityatZeroAntiSweatHeaterEnergy
end
|
#resetInstalledCaseLightingPowerperDoor ⇒ Object
103
104
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 103
def resetInstalledCaseLightingPowerperDoor
end
|
#resetInstalledCaseLightingPowerperUnitLength ⇒ Object
504
505
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 504
def resetInstalledCaseLightingPowerperUnitLength
end
|
#resetLatentCaseCreditCurveType ⇒ Object
483
484
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 483
def resetLatentCaseCreditCurveType
end
|
#resetMinimumAntiSweatHeaterPowerperDoor ⇒ Object
113
114
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 113
def resetMinimumAntiSweatHeaterPowerperDoor
end
|
#resetMinimumAntiSweatHeaterPowerperUnitLength ⇒ Object
524
525
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 524
def resetMinimumAntiSweatHeaterPowerperUnitLength
end
|
#resetNumberOfDoors ⇒ Object
78
79
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 78
def resetNumberOfDoors
end
|
#resetOperatingCaseFanPowerperDoor ⇒ Object
93
94
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 93
def resetOperatingCaseFanPowerperDoor
end
|
#resetOperatingCaseFanPowerperUnitLength ⇒ Object
496
497
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 496
def resetOperatingCaseFanPowerperUnitLength
end
|
#resetRatedAmbientRelativeHumidity ⇒ Object
453
454
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 453
def resetRatedAmbientRelativeHumidity
end
|
#resetRatedAmbientTemperature ⇒ Object
448
449
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 448
def resetRatedAmbientTemperature
end
|
#resetRatedLatentHeatRatio ⇒ Object
463
464
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 463
def resetRatedLatentHeatRatio
end
|
#resetRatedRuntimeFraction ⇒ Object
468
469
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 468
def resetRatedRuntimeFraction
end
|
#resetRatedTotalCoolingCapacityperDoor ⇒ Object
83
84
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 83
def resetRatedTotalCoolingCapacityperDoor
end
|
#resetRatedTotalCoolingCapacityperUnitLength ⇒ Object
458
459
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 458
def resetRatedTotalCoolingCapacityperUnitLength
end
|
#resetRefrigeratedCaseRestockingSchedule ⇒ Object
59
60
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 59
def resetRefrigeratedCaseRestockingSchedule
end
|
#resetStandardCaseFanPowerperDoor ⇒ Object
88
89
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 88
def resetStandardCaseFanPowerperDoor
end
|
#resetStandardCaseFanPowerperUnitLength ⇒ Object
491
492
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 491
def resetStandardCaseFanPowerperUnitLength
end
|
#resetStandardCaseLightingPowerperDoor ⇒ Object
98
99
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 98
def resetStandardCaseLightingPowerperDoor
end
|
#resetStandardCaseLightingPowerperUnitLength ⇒ Object
500
501
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 500
def resetStandardCaseLightingPowerperUnitLength
end
|
#resetThermalZone ⇒ Object
443
444
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 443
def resetThermalZone
end
|
#resetUnderCaseHVACReturnAirFraction ⇒ Object
54
55
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 54
def resetUnderCaseHVACReturnAirFraction
end
|
#resetUnitType ⇒ Object
123
124
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 123
def resetUnitType
end
|
#setAntiSweatHeaterControlType(string) ⇒ Boolean
527
528
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 527
def setAntiSweatHeaterControlType(string)
end
|
#setAvailabilitySchedule(schedule) ⇒ Boolean
436
437
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 436
def setAvailabilitySchedule(schedule)
end
|
#setAverageRefrigerantChargeInventory(double) ⇒ Object
71
72
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 71
def setAverageRefrigerantChargeInventory(double)
end
|
#setCaseAntiSweatHeaterPowerperDoor(double) ⇒ Boolean
106
107
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 106
def setCaseAntiSweatHeaterPowerperDoor(double)
end
|
#setCaseAntiSweatHeaterPowerperUnitLength(double) ⇒ Boolean
517
518
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 517
def setCaseAntiSweatHeaterPowerperUnitLength(double)
end
|
#setCaseCreditFractionSchedule(schedule) ⇒ Boolean
62
63
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 62
def setCaseCreditFractionSchedule(schedule)
end
|
#setCaseDefrostDripDownSchedule(schedule) ⇒ Boolean
37
38
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 37
def setCaseDefrostDripDownSchedule(schedule)
end
|
#setCaseDefrostPowerperDoor(double) ⇒ Boolean
116
117
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 116
def setCaseDefrostPowerperDoor(double)
end
|
#setCaseDefrostPowerperUnitLength(double) ⇒ Boolean
22
23
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 22
def setCaseDefrostPowerperUnitLength(double)
end
|
#setCaseDefrostSchedule(schedule) ⇒ Boolean
32
33
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 32
def setCaseDefrostSchedule(schedule)
end
|
#setCaseDefrostType(string) ⇒ Boolean
27
28
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 27
def setCaseDefrostType(string)
end
|
#setCaseHeight(double) ⇒ Boolean
12
13
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 12
def setCaseHeight(double)
end
|
#setCaseLength(double) ⇒ Boolean
471
472
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 471
def setCaseLength(double)
end
|
#setCaseLightingSchedule(schedule) ⇒ Boolean
507
508
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 507
def setCaseLightingSchedule(schedule)
end
|
#setCaseOperatingTemperature(double) ⇒ Boolean
476
477
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 476
def setCaseOperatingTemperature(double)
end
|
#setDefrost1StartTime(time) ⇒ Boolean
136
137
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 136
def setDefrost1StartTime(time)
end
|
#setDefrost2StartTime(time) ⇒ Boolean
141
142
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 141
def setDefrost2StartTime(time)
end
|
#setDefrost3StartTime(time) ⇒ Boolean
146
147
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 146
def setDefrost3StartTime(time)
end
|
#setDefrost4StartTime(time) ⇒ Boolean
151
152
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 151
def setDefrost4StartTime(time)
end
|
#setDefrost5StartTime(time) ⇒ Boolean
156
157
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 156
def setDefrost5StartTime(time)
end
|
#setDefrost6StartTime(time) ⇒ Boolean
161
162
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 161
def setDefrost6StartTime(time)
end
|
#setDefrost7StartTime(time) ⇒ Boolean
166
167
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 166
def setDefrost7StartTime(time)
end
|
#setDefrost8StartTime(time) ⇒ Boolean
171
172
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 171
def setDefrost8StartTime(time)
end
|
#setDefrostEnergyCorrectionCurve(curveCubic) ⇒ Boolean
47
48
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 47
def setDefrostEnergyCorrectionCurve(curveCubic)
end
|
#setDefrostEnergyCorrectionCurveType(string) ⇒ Boolean
42
43
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 42
def setDefrostEnergyCorrectionCurveType(string)
end
|
#setDesignEvaporatorTemperatureorBrineInletTemperature(double) ⇒ Boolean
67
68
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 67
def setDesignEvaporatorTemperatureorBrineInletTemperature(double)
end
|
#setDripDownTime(int32) ⇒ Boolean
131
132
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 131
def setDripDownTime(int32)
end
|
#setDurationofDefrostCycle(int32) ⇒ Boolean
126
127
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 126
def setDurationofDefrostCycle(int32)
end
|
#setFractionofAntiSweatHeaterEnergytoCase(double) ⇒ Boolean
17
18
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 17
def setFractionofAntiSweatHeaterEnergytoCase(double)
end
|
#setFractionofLightingEnergytoCase(double) ⇒ Boolean
512
513
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 512
def setFractionofLightingEnergytoCase(double)
end
|
#setHumidityatZeroAntiSweatHeaterEnergy(double) ⇒ Object
7
8
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 7
def setHumidityatZeroAntiSweatHeaterEnergy(double)
end
|
#setInstalledCaseLightingPowerperDoor(double) ⇒ Boolean
101
102
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 101
def setInstalledCaseLightingPowerperDoor(double)
end
|
#setInstalledCaseLightingPowerperUnitLength(double) ⇒ Object
502
503
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 502
def setInstalledCaseLightingPowerperUnitLength(double)
end
|
#setLatentCaseCreditCurve(curveCubic) ⇒ Boolean
486
487
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 486
def setLatentCaseCreditCurve(curveCubic)
end
|
#setLatentCaseCreditCurveType(string) ⇒ Boolean
481
482
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 481
def setLatentCaseCreditCurveType(string)
end
|
#setMinimumAntiSweatHeaterPowerperDoor(double) ⇒ Boolean
111
112
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 111
def setMinimumAntiSweatHeaterPowerperDoor(double)
end
|
#setMinimumAntiSweatHeaterPowerperUnitLength(double) ⇒ Boolean
522
523
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 522
def setMinimumAntiSweatHeaterPowerperUnitLength(double)
end
|
#setNumberOfDoors(int32) ⇒ Boolean
76
77
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 76
def setNumberOfDoors(int32)
end
|
#setOperatingCaseFanPowerperDoor(double) ⇒ Boolean
91
92
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 91
def setOperatingCaseFanPowerperDoor(double)
end
|
#setOperatingCaseFanPowerperUnitLength(double) ⇒ Boolean
494
495
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 494
def setOperatingCaseFanPowerperUnitLength(double)
end
|
#setRatedAmbientRelativeHumidity(double) ⇒ Boolean
451
452
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 451
def setRatedAmbientRelativeHumidity(double)
end
|
#setRatedAmbientTemperature(double) ⇒ Boolean
446
447
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 446
def setRatedAmbientTemperature(double)
end
|
#setRatedLatentHeatRatio(double) ⇒ Boolean
461
462
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 461
def setRatedLatentHeatRatio(double)
end
|
#setRatedRuntimeFraction(double) ⇒ Boolean
466
467
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 466
def setRatedRuntimeFraction(double)
end
|
#setRatedTotalCoolingCapacityperDoor(double) ⇒ Boolean
81
82
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 81
def setRatedTotalCoolingCapacityperDoor(double)
end
|
#setRatedTotalCoolingCapacityperUnitLength(double) ⇒ Boolean
456
457
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 456
def setRatedTotalCoolingCapacityperUnitLength(double)
end
|
#setRefrigeratedCaseRestockingSchedule(schedule) ⇒ Boolean
57
58
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 57
def setRefrigeratedCaseRestockingSchedule(schedule)
end
|
#setStandardCaseFanPowerperDoor(double) ⇒ Boolean
86
87
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 86
def setStandardCaseFanPowerperDoor(double)
end
|
#setStandardCaseFanPowerperUnitLength(double) ⇒ Boolean
489
490
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 489
def setStandardCaseFanPowerperUnitLength(double)
end
|
#setStandardCaseLightingPowerperDoor(double) ⇒ Boolean
96
97
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 96
def setStandardCaseLightingPowerperDoor(double)
end
|
#setStandardCaseLightingPowerperUnitLength(double) ⇒ Object
498
499
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 498
def setStandardCaseLightingPowerperUnitLength(double)
end
|
#setThermalZone(thermalZone) ⇒ Boolean
441
442
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 441
def setThermalZone(thermalZone)
end
|
#setUnderCaseHVACReturnAirFraction(double) ⇒ Boolean
52
53
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 52
def setUnderCaseHVACReturnAirFraction(double)
end
|
#setUnitType(string) ⇒ Boolean
121
122
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 121
def setUnitType(string)
end
|
#standardCaseFanPowerperDoor ⇒ OptionalDouble
376
377
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 376
def standardCaseFanPowerperDoor
end
|
#standardCaseFanPowerperUnitLength ⇒ Double
256
257
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 256
def standardCaseFanPowerperUnitLength
end
|
#standardCaseLightingPowerperDoor ⇒ OptionalDouble
382
383
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 382
def standardCaseLightingPowerperDoor
end
|
#standardCaseLightingPowerperUnitLength ⇒ Double
268
269
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 268
def standardCaseLightingPowerperUnitLength
end
|
#system ⇒ SWIGTYPE_p_boost__optionalT_RefrigerationSystem_t
433
434
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 433
def system
end
|
202
203
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 202
def thermalZone
end
|
#underCaseHVACReturnAirFraction ⇒ Double
349
350
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 349
def underCaseHVACReturnAirFraction
end
|
#unitType ⇒ String
397
398
|
# File 'lib/openstudio-api-stubs/Classes/RefrigerationCase.rb', line 397
def unitType
end
|