Class: OpenStudio::Model::CoolingTowerVariableSpeed
Class Method Summary
collapse
Instance Method Summary
collapse
#addToNode, #airLoopHVAC, #clone, #disconnect, #inletModelObject, #inletPort, #outletModelObject, #outletPort, #remove, #removeFromLoop
#addToNode, #addToSplitter, #airLoopHVAC, #airLoopHVACOutdoorAirSystem, #containingHVACComponent, #containingStraightComponent, #containingZoneHVACComponent, #disconnect, #isRemovable, #loop, #plantLoop, #remove
#allowableChildTypes, #children
Methods inherited from ModelObject
#EqualEqual, #LessThan, #NotEqual, #__str__, #clone, #connectedObject, #connectedObjectPort, #createComponent, #getData, #getScheduleTypeKeys, #iddObjectType, #lifeCycleCosts, #model, #outputVariableNames, #outputVariables, #parent, #removeLifeCycleCosts, #resources, #setParent, #toIdfObject
#LessThan, #__str__, #canBeSource, #canBeTarget, #getSourceIndices, #getSources, #getTarget, #idfObject, #initialized, #isSource, #isTarget, #numSources, #objectListFieldsEqual, #objectListFieldsNonConflicting, #remove, #setPointer, #sources, #targets, #workspace
Class Method Details
.blowdownCalculationModeValues ⇒ StringVector
17
18
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 17
def self.blowdownCalculationModeValues
end
|
.cellControlValues ⇒ StringVector
20
21
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 20
def self.cellControlValues
end
|
.evaporationLossModeValues ⇒ StringVector
14
15
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 14
def self.evaporationLossModeValues
end
|
8
9
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 8
def self.iddObjectType
end
|
.modelTypeValues ⇒ StringVector
11
12
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 11
def self.modelTypeValues
end
|
.new(model) ⇒ Object
5
6
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 5
def self.new(model)
end
|
Instance Method Details
#autosizeDesignAirFlowRate ⇒ Object
82
83
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 82
def autosizeDesignAirFlowRate
end
|
#autosizeDesignFanPower ⇒ Object
93
94
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 93
def autosizeDesignFanPower
end
|
#autosizeDesignWaterFlowRate ⇒ Object
71
72
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 71
def autosizeDesignWaterFlowRate
end
|
120
121
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 120
def basinHeaterCapacity
end
|
136
137
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 136
def basinHeaterOperatingSchedule
end
|
#basinHeaterSetpointTemperature ⇒ OptionalDouble
128
129
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 128
def basinHeaterSetpointTemperature
end
|
169
170
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 169
def blowdownCalculationMode
end
|
#blowdownConcentrationRatio ⇒ OptionalDouble
177
178
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 177
def blowdownConcentrationRatio
end
|
#blowdownMakeupWaterUsageSchedule ⇒ OptionalSchedule
185
186
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 185
def blowdownMakeupWaterUsageSchedule
end
|
201
202
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 201
def cellControl
end
|
#cellMaximumWaterFlowRateFraction ⇒ OptionalDouble
217
218
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 217
def cellMaximumWaterFlowRateFraction
end
|
#cellMinimumWaterFlowRateFraction ⇒ OptionalDouble
209
210
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 209
def cellMinimumWaterFlowRateFraction
end
|
74
75
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 74
def designAirFlowRate
end
|
#designApproachTemperature ⇒ OptionalDouble
47
48
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 47
def designApproachTemperature
end
|
85
86
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 85
def designFanPower
end
|
#designInletAirWetBulbTemperature ⇒ OptionalDouble
39
40
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 39
def designInletAirWetBulbTemperature
end
|
55
56
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 55
def designRangeTemperature
end
|
63
64
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 63
def designWaterFlowRate
end
|
162
163
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 162
def driftLossPercent
end
|
#evaporationLossFactor ⇒ Double
152
153
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 152
def evaporationLossFactor
end
|
144
145
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 144
def evaporationLossMode
end
|
#fanPowerRatioFunctionofAirFlowRateRatioCurve ⇒ OptionalCurveCubic
96
97
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 96
def fanPowerRatioFunctionofAirFlowRateRatioCurve
end
|
#fractionofTowerCapacityinFreeConvectionRegime ⇒ OptionalDouble
112
113
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 112
def fractionofTowerCapacityinFreeConvectionRegime
end
|
#isDesignAirFlowRateAutosized ⇒ Boolean
77
78
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 77
def isDesignAirFlowRateAutosized
end
|
#isDesignFanPowerAutosized ⇒ Boolean
88
89
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 88
def isDesignFanPowerAutosized
end
|
#isDesignWaterFlowRateAutosized ⇒ Boolean
66
67
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 66
def isDesignWaterFlowRateAutosized
end
|
#isEvaporationLossFactorDefaulted ⇒ Boolean
155
156
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 155
def isEvaporationLossFactorDefaulted
end
|
104
105
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 104
def minimumAirFlowRateRatio
end
|
31
32
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 31
def modelCoefficient
end
|
23
24
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 23
def modelType
end
|
193
194
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 193
def numberofCells
end
|
#resetBasinHeaterCapacity ⇒ Object
125
126
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 125
def resetBasinHeaterCapacity
end
|
#resetBasinHeaterOperatingSchedule ⇒ Object
141
142
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 141
def resetBasinHeaterOperatingSchedule
end
|
#resetBasinHeaterSetpointTemperature ⇒ Object
133
134
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 133
def resetBasinHeaterSetpointTemperature
end
|
#resetBlowdownCalculationMode ⇒ Object
174
175
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 174
def resetBlowdownCalculationMode
end
|
#resetBlowdownConcentrationRatio ⇒ Object
182
183
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 182
def resetBlowdownConcentrationRatio
end
|
#resetBlowdownMakeupWaterUsageSchedule ⇒ Object
190
191
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 190
def resetBlowdownMakeupWaterUsageSchedule
end
|
#resetCellControl ⇒ Object
206
207
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 206
def resetCellControl
end
|
#resetCellMaximumWaterFlowRateFraction ⇒ Object
222
223
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 222
def resetCellMaximumWaterFlowRateFraction
end
|
#resetCellMinimumWaterFlowRateFraction ⇒ Object
214
215
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 214
def resetCellMinimumWaterFlowRateFraction
end
|
#resetDesignApproachTemperature ⇒ Object
52
53
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 52
def resetDesignApproachTemperature
end
|
#resetDesignInletAirWetBulbTemperature ⇒ Object
44
45
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 44
def resetDesignInletAirWetBulbTemperature
end
|
#resetDesignRangeTemperature ⇒ Object
60
61
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 60
def resetDesignRangeTemperature
end
|
#resetDriftLossPercent ⇒ Object
166
167
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 166
def resetDriftLossPercent
end
|
#resetEvaporationLossFactor ⇒ Object
159
160
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 159
def resetEvaporationLossFactor
end
|
#resetEvaporationLossMode ⇒ Object
149
150
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 149
def resetEvaporationLossMode
end
|
#resetFanPowerRatioFunctionofAirFlowRateRatioCurve ⇒ Object
101
102
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 101
def resetFanPowerRatioFunctionofAirFlowRateRatioCurve
end
|
#resetFractionofTowerCapacityinFreeConvectionRegime ⇒ Object
117
118
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 117
def resetFractionofTowerCapacityinFreeConvectionRegime
end
|
#resetMinimumAirFlowRateRatio ⇒ Object
109
110
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 109
def resetMinimumAirFlowRateRatio
end
|
#resetModelCoefficient ⇒ Object
36
37
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 36
def resetModelCoefficient
end
|
#resetModelType ⇒ Object
28
29
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 28
def resetModelType
end
|
#resetNumberofCells ⇒ Object
198
199
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 198
def resetNumberofCells
end
|
#resetSizingFactor ⇒ Object
230
231
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 230
def resetSizingFactor
end
|
#setBasinHeaterCapacity(double) ⇒ Boolean
123
124
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 123
def setBasinHeaterCapacity(double)
end
|
#setBasinHeaterOperatingSchedule(schedule) ⇒ Boolean
139
140
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 139
def setBasinHeaterOperatingSchedule(schedule)
end
|
#setBasinHeaterSetpointTemperature(double) ⇒ Boolean
131
132
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 131
def setBasinHeaterSetpointTemperature(double)
end
|
#setBlowdownCalculationMode(string) ⇒ Boolean
172
173
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 172
def setBlowdownCalculationMode(string)
end
|
#setBlowdownConcentrationRatio(double) ⇒ Boolean
180
181
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 180
def setBlowdownConcentrationRatio(double)
end
|
#setBlowdownMakeupWaterUsageSchedule(schedule) ⇒ Boolean
188
189
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 188
def setBlowdownMakeupWaterUsageSchedule(schedule)
end
|
#setCellControl(string) ⇒ Boolean
204
205
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 204
def setCellControl(string)
end
|
#setCellMaximumWaterFlowRateFraction(double) ⇒ Boolean
220
221
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 220
def setCellMaximumWaterFlowRateFraction(double)
end
|
#setCellMinimumWaterFlowRateFraction(double) ⇒ Boolean
212
213
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 212
def setCellMinimumWaterFlowRateFraction(double)
end
|
#setDesignAirFlowRate(double) ⇒ Boolean
80
81
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 80
def setDesignAirFlowRate(double)
end
|
#setDesignApproachTemperature(double) ⇒ Boolean
50
51
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 50
def setDesignApproachTemperature(double)
end
|
#setDesignFanPower(double) ⇒ Boolean
91
92
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 91
def setDesignFanPower(double)
end
|
#setDesignInletAirWetBulbTemperature(double) ⇒ Boolean
42
43
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 42
def setDesignInletAirWetBulbTemperature(double)
end
|
#setDesignRangeTemperature(double) ⇒ Boolean
58
59
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 58
def setDesignRangeTemperature(double)
end
|
#setDesignWaterFlowRate(double) ⇒ Boolean
69
70
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 69
def setDesignWaterFlowRate(double)
end
|
#setDriftLossPercent(double) ⇒ Object
164
165
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 164
def setDriftLossPercent(double)
end
|
#setEvaporationLossFactor(double) ⇒ Object
157
158
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 157
def setEvaporationLossFactor(double)
end
|
#setEvaporationLossMode(string) ⇒ Boolean
147
148
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 147
def setEvaporationLossMode(string)
end
|
#setFanPowerRatioFunctionofAirFlowRateRatioCurve(curveCubic) ⇒ Boolean
99
100
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 99
def setFanPowerRatioFunctionofAirFlowRateRatioCurve(curveCubic)
end
|
#setFractionofTowerCapacityinFreeConvectionRegime(double) ⇒ Boolean
115
116
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 115
def setFractionofTowerCapacityinFreeConvectionRegime(double)
end
|
#setMinimumAirFlowRateRatio(double) ⇒ Boolean
107
108
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 107
def setMinimumAirFlowRateRatio(double)
end
|
#setModelCoefficient(modelObject) ⇒ Boolean
34
35
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 34
def setModelCoefficient(modelObject)
end
|
#setModelType(string) ⇒ Boolean
26
27
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 26
def setModelType(string)
end
|
#setNumberofCells(int32) ⇒ Boolean
196
197
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 196
def setNumberofCells(int32)
end
|
#setSizingFactor(double) ⇒ Boolean
228
229
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 228
def setSizingFactor(double)
end
|
225
226
|
# File 'lib/openstudio-api-stubs/Classes/CoolingTowerVariableSpeed.rb', line 225
def sizingFactor
end
|