Class: Honeybee::VentilationSimulationControl
- Inherits:
-
ModelObject
- Object
- ModelObject
- Honeybee::VentilationSimulationControl
- Defined in:
- lib/honeybee/ventcool/simulation.rb,
lib/to_openstudio/ventcool/simulation.rb
Instance Attribute Summary
Attributes inherited from ModelObject
#errors, #openstudio_object, #warnings
Instance Method Summary collapse
Methods inherited from ModelObject
#allowable_types, clean_identifier, clean_name, #find_existing_openstudio_object, #initialize, #method_missing, read_from_disk, truncate
Constructor Details
This class inherits a constructor from Honeybee::ModelObject
Dynamic Method Handling
This class handles dynamic methods through the method_missing method in the class Honeybee::ModelObject
Instance Method Details
#defaults ⇒ Object
37 38 39 |
# File 'lib/honeybee/ventcool/simulation.rb', line 37 def defaults @@schema[:components][:schemas][:VentilationSimulationControl][:properties] end |
#to_openstudio(openstudio_model) ⇒ Object
39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 |
# File 'lib/to_openstudio/ventcool/simulation.rb', line 39 def to_openstudio(openstudio_model) # create the AirflowNetworkSimulationControl object os_vsim_control = openstudio_model.getAirflowNetworkSimulationControl os_vsim_control.setName('Window Based Ventilative Cooling') # assign the control type if @hash[:vent_control_type] os_vsim_control.setAirflowNetworkControl(@hash[:vent_control_type]) else os_vsim_control.setAirflowNetworkControl('MultizoneWithoutDistribution') end # assign the building type if @hash[:building_type] os_vsim_control.setBuildingType(@hash[:building_type]) else os_vsim_control.setBuildingType(defaults[:building_type][:default]) end # assign the long axis azimth angle of the building if @hash[:long_axis_angle] os_vsim_control.setAzimuthAngleofLongAxisofBuilding(@hash[:long_axis_angle]) else os_vsim_control.setAzimuthAngleofLongAxisofBuilding(defaults[:long_axis_angle][:default]) end # assign the aspect ratio of the building if @hash[:aspect_ratio] os_vsim_control.setBuildingAspectRatio(@hash[:aspect_ratio]) else os_vsim_control.setBuildingAspectRatio(defaults[:aspect_ratio][:default]) end # create the AirflowNetworkReferenceCrackConditions object that all other cracks reference os_ref_crack = OpenStudio::Model::AirflowNetworkReferenceCrackConditions.new(openstudio_model) os_ref_crack.setName('Reference Crack Conditions') # assign the reference temperature if @hash[:reference_temperature] os_ref_crack.setTemperature(@hash[:reference_temperature]) else os_ref_crack.setTemperature(defaults[:reference_temperature][:default]) end # assign the reference pressure if @hash[:reference_pressure] os_ref_crack.setBarometricPressure(@hash[:reference_pressure]) else os_ref_crack.setBarometricPressure(defaults[:reference_pressure][:default]) end # assign the reference humidity ratio if @hash[:reference_humidity_ratio] os_ref_crack.setHumidityRatio(@hash[:reference_humidity_ratio]) else os_ref_crack.setHumidityRatio(defaults[:reference_humidity_ratio][:default]) end os_ref_crack end |