Class: Google::Cloud::Compute::V1::InterconnectDiagnosticsLinkOpticalPower
- Inherits:
-
Object
- Object
- Google::Cloud::Compute::V1::InterconnectDiagnosticsLinkOpticalPower
- Extended by:
- Protobuf::MessageExts::ClassMethods
- Includes:
- Protobuf::MessageExts
- Defined in:
- proto_docs/google/cloud/compute/v1/compute.rb
Defined Under Namespace
Modules: State
Instance Attribute Summary collapse
-
#state ⇒ ::String
The status of the current value when compared to the warning and alarm levels for the receiving or transmitting transceiver.
-
#value ⇒ ::Float
Value of the current receiving or transmitting optical power, read in dBm.
Instance Attribute Details
#state ⇒ ::String
Returns The status of the current value when compared to the warning and alarm levels for the receiving or transmitting transceiver. Possible states include: - OK: The value has not crossed a warning threshold. - LOW_WARNING: The value has crossed below the low warning threshold. - HIGH_WARNING: The value has crossed above the high warning threshold. - LOW_ALARM: The value has crossed below the low alarm threshold. - HIGH_ALARM: The value has crossed above the high alarm threshold. Check the State enum for the list of possible values.
13844 13845 13846 13847 13848 13849 13850 13851 13852 13853 13854 13855 13856 13857 13858 13859 13860 13861 13862 13863 13864 13865 13866 13867 13868 |
# File 'proto_docs/google/cloud/compute/v1/compute.rb', line 13844 class InterconnectDiagnosticsLinkOpticalPower include ::Google::Protobuf::MessageExts extend ::Google::Protobuf::MessageExts::ClassMethods # The status of the current value when compared to the warning and alarm levels for the receiving or transmitting transceiver. Possible states include: - OK: The value has not crossed a warning threshold. - LOW_WARNING: The value has crossed below the low warning threshold. - HIGH_WARNING: The value has crossed above the high warning threshold. - LOW_ALARM: The value has crossed below the low alarm threshold. - HIGH_ALARM: The value has crossed above the high alarm threshold. module State # A value indicating that the enum field is not set. UNDEFINED_STATE = 0 # The value has crossed above the high alarm threshold. HIGH_ALARM = 305363284 # The value of the current optical power has crossed above the high warning threshold. HIGH_WARNING = 220984799 # The value of the current optical power has crossed below the low alarm threshold. LOW_ALARM = 316659046 # The value of the current optical power has crossed below the low warning threshold. LOW_WARNING = 338793841 # The value of the current optical power has not crossed a warning threshold. OK = 2524 end end |
#value ⇒ ::Float
Returns Value of the current receiving or transmitting optical power, read in dBm. Take a known good optical value, give it a 10% margin and trigger warnings relative to that value. In general, a -7dBm warning and a -11dBm alarm are good optical value estimates for most links.
13844 13845 13846 13847 13848 13849 13850 13851 13852 13853 13854 13855 13856 13857 13858 13859 13860 13861 13862 13863 13864 13865 13866 13867 13868 |
# File 'proto_docs/google/cloud/compute/v1/compute.rb', line 13844 class InterconnectDiagnosticsLinkOpticalPower include ::Google::Protobuf::MessageExts extend ::Google::Protobuf::MessageExts::ClassMethods # The status of the current value when compared to the warning and alarm levels for the receiving or transmitting transceiver. Possible states include: - OK: The value has not crossed a warning threshold. - LOW_WARNING: The value has crossed below the low warning threshold. - HIGH_WARNING: The value has crossed above the high warning threshold. - LOW_ALARM: The value has crossed below the low alarm threshold. - HIGH_ALARM: The value has crossed above the high alarm threshold. module State # A value indicating that the enum field is not set. UNDEFINED_STATE = 0 # The value has crossed above the high alarm threshold. HIGH_ALARM = 305363284 # The value of the current optical power has crossed above the high warning threshold. HIGH_WARNING = 220984799 # The value of the current optical power has crossed below the low alarm threshold. LOW_ALARM = 316659046 # The value of the current optical power has crossed below the low warning threshold. LOW_WARNING = 338793841 # The value of the current optical power has not crossed a warning threshold. OK = 2524 end end |