Class: Google::Cloud::Compute::V1::InterconnectDiagnosticsLinkOpticalPower

Inherits:
Object
  • Object
show all
Extended by:
Protobuf::MessageExts::ClassMethods
Includes:
Protobuf::MessageExts
Defined in:
proto_docs/google/cloud/compute/v1/compute.rb

Defined Under Namespace

Modules: State

Instance Attribute Summary collapse

Instance Attribute Details

#state::String

Returns The status of the current value when compared to the warning and alarm levels for the receiving or transmitting transceiver. Possible states include: - OK: The value has not crossed a warning threshold. - LOW_WARNING: The value has crossed below the low warning threshold. - HIGH_WARNING: The value has crossed above the high warning threshold. - LOW_ALARM: The value has crossed below the low alarm threshold. - HIGH_ALARM: The value has crossed above the high alarm threshold. Check the State enum for the list of possible values.

Returns:

  • (::String)

    The status of the current value when compared to the warning and alarm levels for the receiving or transmitting transceiver. Possible states include: - OK: The value has not crossed a warning threshold. - LOW_WARNING: The value has crossed below the low warning threshold. - HIGH_WARNING: The value has crossed above the high warning threshold. - LOW_ALARM: The value has crossed below the low alarm threshold. - HIGH_ALARM: The value has crossed above the high alarm threshold. Check the State enum for the list of possible values.



13844
13845
13846
13847
13848
13849
13850
13851
13852
13853
13854
13855
13856
13857
13858
13859
13860
13861
13862
13863
13864
13865
13866
13867
13868
# File 'proto_docs/google/cloud/compute/v1/compute.rb', line 13844

class InterconnectDiagnosticsLinkOpticalPower
  include ::Google::Protobuf::MessageExts
  extend ::Google::Protobuf::MessageExts::ClassMethods

  # The status of the current value when compared to the warning and alarm levels for the receiving or transmitting transceiver. Possible states include: - OK: The value has not crossed a warning threshold. - LOW_WARNING: The value has crossed below the low warning threshold. - HIGH_WARNING: The value has crossed above the high warning threshold. - LOW_ALARM: The value has crossed below the low alarm threshold. - HIGH_ALARM: The value has crossed above the high alarm threshold.
  module State
    # A value indicating that the enum field is not set.
    UNDEFINED_STATE = 0

    # The value has crossed above the high alarm threshold.
    HIGH_ALARM = 305363284

    # The value of the current optical power has crossed above the high warning threshold.
    HIGH_WARNING = 220984799

    # The value of the current optical power has crossed below the low alarm threshold.
    LOW_ALARM = 316659046

    # The value of the current optical power has crossed below the low warning threshold.
    LOW_WARNING = 338793841

    # The value of the current optical power has not crossed a warning threshold.
    OK = 2524
  end
end

#value::Float

Returns Value of the current receiving or transmitting optical power, read in dBm. Take a known good optical value, give it a 10% margin and trigger warnings relative to that value. In general, a -7dBm warning and a -11dBm alarm are good optical value estimates for most links.

Returns:

  • (::Float)

    Value of the current receiving or transmitting optical power, read in dBm. Take a known good optical value, give it a 10% margin and trigger warnings relative to that value. In general, a -7dBm warning and a -11dBm alarm are good optical value estimates for most links.



13844
13845
13846
13847
13848
13849
13850
13851
13852
13853
13854
13855
13856
13857
13858
13859
13860
13861
13862
13863
13864
13865
13866
13867
13868
# File 'proto_docs/google/cloud/compute/v1/compute.rb', line 13844

class InterconnectDiagnosticsLinkOpticalPower
  include ::Google::Protobuf::MessageExts
  extend ::Google::Protobuf::MessageExts::ClassMethods

  # The status of the current value when compared to the warning and alarm levels for the receiving or transmitting transceiver. Possible states include: - OK: The value has not crossed a warning threshold. - LOW_WARNING: The value has crossed below the low warning threshold. - HIGH_WARNING: The value has crossed above the high warning threshold. - LOW_ALARM: The value has crossed below the low alarm threshold. - HIGH_ALARM: The value has crossed above the high alarm threshold.
  module State
    # A value indicating that the enum field is not set.
    UNDEFINED_STATE = 0

    # The value has crossed above the high alarm threshold.
    HIGH_ALARM = 305363284

    # The value of the current optical power has crossed above the high warning threshold.
    HIGH_WARNING = 220984799

    # The value of the current optical power has crossed below the low alarm threshold.
    LOW_ALARM = 316659046

    # The value of the current optical power has crossed below the low warning threshold.
    LOW_WARNING = 338793841

    # The value of the current optical power has not crossed a warning threshold.
    OK = 2524
  end