Class: Google::Cloud::Compute::V1::InterconnectDiagnosticsLinkOpticalPower
- Inherits:
-
Object
- Object
- Google::Cloud::Compute::V1::InterconnectDiagnosticsLinkOpticalPower
- Extended by:
- Protobuf::MessageExts::ClassMethods
- Includes:
- Protobuf::MessageExts
- Defined in:
- proto_docs/google/cloud/compute/v1/compute.rb
Defined Under Namespace
Modules: State
Instance Attribute Summary collapse
-
#state ⇒ ::String
The status of the current value when compared to the warning and alarm levels for the receiving or transmitting transceiver.
-
#value ⇒ ::Float
Value of the current receiving or transmitting optical power, read in dBm.
Instance Attribute Details
#state ⇒ ::String
Returns The status of the current value when compared to the warning and alarm levels for the receiving or transmitting transceiver. Possible states include: - OK: The value has not crossed a warning threshold. - LOW_WARNING: The value has crossed below the low warning threshold. - HIGH_WARNING: The value has crossed above the high warning threshold. - LOW_ALARM: The value has crossed below the low alarm threshold. - HIGH_ALARM: The value has crossed above the high alarm threshold. Check the State enum for the list of possible values.
13539 13540 13541 13542 13543 13544 13545 13546 13547 13548 13549 13550 13551 13552 13553 13554 13555 13556 13557 13558 13559 13560 13561 13562 13563 |
# File 'proto_docs/google/cloud/compute/v1/compute.rb', line 13539 class InterconnectDiagnosticsLinkOpticalPower include ::Google::Protobuf::MessageExts extend ::Google::Protobuf::MessageExts::ClassMethods # The status of the current value when compared to the warning and alarm levels for the receiving or transmitting transceiver. Possible states include: - OK: The value has not crossed a warning threshold. - LOW_WARNING: The value has crossed below the low warning threshold. - HIGH_WARNING: The value has crossed above the high warning threshold. - LOW_ALARM: The value has crossed below the low alarm threshold. - HIGH_ALARM: The value has crossed above the high alarm threshold. module State # A value indicating that the enum field is not set. UNDEFINED_STATE = 0 # The value has crossed above the high alarm threshold. HIGH_ALARM = 305363284 # The value of the current optical power has crossed above the high warning threshold. HIGH_WARNING = 220984799 # The value of the current optical power has crossed below the low alarm threshold. LOW_ALARM = 316659046 # The value of the current optical power has crossed below the low warning threshold. LOW_WARNING = 338793841 # The value of the current optical power has not crossed a warning threshold. OK = 2524 end end |
#value ⇒ ::Float
Returns Value of the current receiving or transmitting optical power, read in dBm. Take a known good optical value, give it a 10% margin and trigger warnings relative to that value. In general, a -7dBm warning and a -11dBm alarm are good optical value estimates for most links.
13539 13540 13541 13542 13543 13544 13545 13546 13547 13548 13549 13550 13551 13552 13553 13554 13555 13556 13557 13558 13559 13560 13561 13562 13563 |
# File 'proto_docs/google/cloud/compute/v1/compute.rb', line 13539 class InterconnectDiagnosticsLinkOpticalPower include ::Google::Protobuf::MessageExts extend ::Google::Protobuf::MessageExts::ClassMethods # The status of the current value when compared to the warning and alarm levels for the receiving or transmitting transceiver. Possible states include: - OK: The value has not crossed a warning threshold. - LOW_WARNING: The value has crossed below the low warning threshold. - HIGH_WARNING: The value has crossed above the high warning threshold. - LOW_ALARM: The value has crossed below the low alarm threshold. - HIGH_ALARM: The value has crossed above the high alarm threshold. module State # A value indicating that the enum field is not set. UNDEFINED_STATE = 0 # The value has crossed above the high alarm threshold. HIGH_ALARM = 305363284 # The value of the current optical power has crossed above the high warning threshold. HIGH_WARNING = 220984799 # The value of the current optical power has crossed below the low alarm threshold. LOW_ALARM = 316659046 # The value of the current optical power has crossed below the low warning threshold. LOW_WARNING = 338793841 # The value of the current optical power has not crossed a warning threshold. OK = 2524 end end |