Class: Aws::SWF::Types::StartChildWorkflowExecutionFailedEventAttributes
- Inherits:
-
Struct
- Object
- Struct
- Aws::SWF::Types::StartChildWorkflowExecutionFailedEventAttributes
- Includes:
- Aws::Structure
- Defined in:
- lib/aws-sdk-swf/types.rb
Overview
Provides the details of the StartChildWorkflowExecutionFailed event.
Constant Summary collapse
- SENSITIVE =
[]
Instance Attribute Summary collapse
-
#cause ⇒ String
The cause of the failure.
-
#control ⇒ String
The data attached to the event that the decider can use in subsequent workflow tasks.
-
#decision_task_completed_event_id ⇒ Integer
The ID of the
DecisionTaskCompletedevent corresponding to the decision task that resulted in theStartChildWorkflowExecutionDecision to request this child workflow execution. -
#initiated_event_id ⇒ Integer
When the
causeisWORKFLOW_ALREADY_RUNNING,initiatedEventIdis the ID of theStartChildWorkflowExecutionInitiatedevent that corresponds to theStartChildWorkflowExecutionDecision to start the workflow execution. -
#workflow_id ⇒ String
The
workflowIdof the child workflow execution. -
#workflow_type ⇒ Types::WorkflowType
The workflow type provided in the
StartChildWorkflowExecutionDecision that failed.
Instance Attribute Details
#cause ⇒ String
The cause of the failure. This information is generated by the system and can be useful for diagnostic purposes.
<note markdown=“1”> When cause is set to OPERATION_NOT_PERMITTED, the decision fails because it lacks sufficient permissions. For details and example IAM policies, see [ Using IAM to Manage Access to Amazon SWF Workflows] in the *Amazon SWF Developer Guide*.
</note>
[1]: docs.aws.amazon.com/amazonswf/latest/developerguide/swf-dev-iam.html
4975 4976 4977 4978 4979 4980 4981 4982 4983 4984 |
# File 'lib/aws-sdk-swf/types.rb', line 4975 class StartChildWorkflowExecutionFailedEventAttributes < Struct.new( :workflow_type, :cause, :workflow_id, :initiated_event_id, :decision_task_completed_event_id, :control) SENSITIVE = [] include Aws::Structure end |
#control ⇒ String
The data attached to the event that the decider can use in subsequent workflow tasks. This data isn’t sent to the child workflow execution.
4975 4976 4977 4978 4979 4980 4981 4982 4983 4984 |
# File 'lib/aws-sdk-swf/types.rb', line 4975 class StartChildWorkflowExecutionFailedEventAttributes < Struct.new( :workflow_type, :cause, :workflow_id, :initiated_event_id, :decision_task_completed_event_id, :control) SENSITIVE = [] include Aws::Structure end |
#decision_task_completed_event_id ⇒ Integer
The ID of the DecisionTaskCompleted event corresponding to the decision task that resulted in the StartChildWorkflowExecution Decision to request this child workflow execution. This information can be useful for diagnosing problems by tracing back the chain of events.
4975 4976 4977 4978 4979 4980 4981 4982 4983 4984 |
# File 'lib/aws-sdk-swf/types.rb', line 4975 class StartChildWorkflowExecutionFailedEventAttributes < Struct.new( :workflow_type, :cause, :workflow_id, :initiated_event_id, :decision_task_completed_event_id, :control) SENSITIVE = [] include Aws::Structure end |
#initiated_event_id ⇒ Integer
When the cause is WORKFLOW_ALREADY_RUNNING, initiatedEventId is the ID of the StartChildWorkflowExecutionInitiated event that corresponds to the StartChildWorkflowExecution Decision to start the workflow execution. You can use this information to diagnose problems by tracing back the chain of events leading up to this event.
When the cause isn’t WORKFLOW_ALREADY_RUNNING, initiatedEventId is set to 0 because the StartChildWorkflowExecutionInitiated event doesn’t exist.
4975 4976 4977 4978 4979 4980 4981 4982 4983 4984 |
# File 'lib/aws-sdk-swf/types.rb', line 4975 class StartChildWorkflowExecutionFailedEventAttributes < Struct.new( :workflow_type, :cause, :workflow_id, :initiated_event_id, :decision_task_completed_event_id, :control) SENSITIVE = [] include Aws::Structure end |
#workflow_id ⇒ String
The workflowId of the child workflow execution.
4975 4976 4977 4978 4979 4980 4981 4982 4983 4984 |
# File 'lib/aws-sdk-swf/types.rb', line 4975 class StartChildWorkflowExecutionFailedEventAttributes < Struct.new( :workflow_type, :cause, :workflow_id, :initiated_event_id, :decision_task_completed_event_id, :control) SENSITIVE = [] include Aws::Structure end |
#workflow_type ⇒ Types::WorkflowType
The workflow type provided in the StartChildWorkflowExecution Decision that failed.
4975 4976 4977 4978 4979 4980 4981 4982 4983 4984 |
# File 'lib/aws-sdk-swf/types.rb', line 4975 class StartChildWorkflowExecutionFailedEventAttributes < Struct.new( :workflow_type, :cause, :workflow_id, :initiated_event_id, :decision_task_completed_event_id, :control) SENSITIVE = [] include Aws::Structure end |