- HEIGHT_CATEGORIES =
Height category constants based on EN 14960:2019
{ 1000 => {label: "1.0m (Young children)", max_users: :calculate_by_area}, 1200 => {label: "1.2m (Children)", max_users: :calculate_by_area}, 1500 => {label: "1.5m (Adolescents)", max_users: :calculate_by_area}, 1800 => {label: "1.8m (Adults)", max_users: :calculate_by_area} }.freeze
- GROUNDING_TEST_WEIGHTS =
Grounding test weights by user height (EN 14960:2019)
{ height_1000mm: 25, # kg test weight for 1.0m users height_1200mm: 35, # kg test weight for 1.2m users height_1500mm: 65, # kg test weight for 1.5m users height_1800mm: 85 # kg test weight for 1.8m users }.freeze
- REINSPECTION_INTERVAL_DAYS =
Reinspection interval
365- ANCHOR_CALCULATION_CONSTANTS =
Anchor calculation constants from EN 14960-1:2019 Line 450: Each anchor must withstand 1600N force Lines 441-442: Minimum 6 anchorage points required Lines 1194-1199: Cw=1.5, ρ=1.24 kg/m³, V=11.1 m/s Pre-calculated: 0.5 × 1.5 × 1.24 × 11.1² ≈ 114
{ area_coefficient: 114.0, # Pre-calculated wind force coefficient base_divisor: 1600.0, # Force per anchor in Newtons (Line 450) safety_factor: 1.5, # Safety factor multiplier minimum_anchors: 6 # Minimum required anchors (Lines 441-442) }.freeze
- SLIDE_HEIGHT_THRESHOLDS =
Slide safety thresholds
{ no_walls_required: 0.6, # Under 600mm basic_walls: 3.0, # 600mm - 3000mm enhanced_walls: 6.0, # 3000mm - 6000mm max_safe_height: 8.0 # Maximum recommended height }.freeze
- RUNOUT_CALCULATION_CONSTANTS =
Slide runout calculation constants (EN 14960:2019)
{ platform_height_ratio: 0.5, # 50% of platform height minimum_runout_meters: 0.3, # Absolute minimum 300mm (0.3m) stop_wall_addition: 0.5 # 50cm addition when stop-wall fitted (Line 936) }.freeze
- WALL_HEIGHT_CONSTANTS =
Wall height calculation constants (EN 14960:2019)
{ enhanced_height_multiplier: 1.25 # 1.25× multiplier for enhanced walls }.freeze
- AREA_DIVISOR =
EN 14960-1:2019 Section 4.3 (Lines 940-961) - Number of users Note: EN 14960 doesn’t specify exact calculation formulas, only factors to consider:
-
Height of user (Line 946)
-
Size of playing area (Line 954)
-
Type of activity (Line 956)
The calculation below is industry standard practice, not from EN 14960
-
{ 1000 => 1.0, # 1 user per m² for 1.0m height 1200 => 1.33, # 0.75 users per m² for 1.2m height 1500 => 1.66, # 0.60 users per m² for 1.5m height 1800 => 2.0 # 0.5 users per m² for 1.8m height }.freeze
- USER_CAPACITY_CONSTANTS =
User capacity constants - space required per user by height
{ space_per_user_1000mm: 1.0, # 1 m² per user for 1.0m height space_per_user_1200mm: 1.33, # 1.33 m² per user for 1.2m height space_per_user_1500mm: 1.66, # 1.66 m² per user for 1.5m height space_per_user_1800mm: 2.0 # 2 m² per user for 1.8m height }.freeze
- MATERIAL_STANDARDS =
Material safety standards (EN 14960:2019 & EN 71-3)
{ fabric: { min_tensile_strength: 1850, # Newtons minimum min_tear_strength: 350, # Newtons minimum fire_standard: "EN 71-3" # Fire retardancy standard }, thread: { min_tensile_strength: 88 # Newtons minimum }, rope: { min_diameter: 18, # mm minimum max_diameter: 45, # mm maximum max_swing_percentage: 20 # % maximum swing }, netting: { max_vertical_mesh: 30, # mm maximum for >1m height max_roof_mesh: 8 # mm maximum } }.freeze