Radfish - Unified Redfish Client
A Ruby client library that provides a unified interface for managing servers via Redfish API, with automatic vendor detection and adaptation.
Data Normalization
Radfish takes a minimal approach to data normalization to ensure consistency across different systems and avoid mismatches from varying formats:
- Manufacturer/Make: Returns simplified vendor names (e.g., "Dell" instead of "Dell Inc.", "Supermicro" instead of "Super Micro Computer")
- Model: Returns core model identifiers without marketing prefixes (e.g., "R640" instead of "PowerEdge R640")
- Consistent Fields: All adapters normalize their data to use the same field names and formats
This approach minimizes potential mismatches across older systems or spacing/hyphenation issues with multi-token descriptors.
Architecture
Radfish provides a vendor-agnostic interface for server management through Redfish, automatically detecting and adapting to different hardware vendors. The architecture consists of:
radfish (core gem)
The HTTP layer
Radfish::HttpClient is the single seam between the library and the network.
Faraday is an implementation detail behind it: the vendor detector, the core
classes and the adapters talk to HttpClient (or to BaseClient#http_get and
friends, which delegate to it) and never build a Faraday connection of their
own. Everything that BMCs make awkward lives in that one class - permissive TLS
for old firmware, the Host header for SSH tunnels, retries, redirects, debug
logging, and the translation of transport failures into Radfish errors.
Two consequences worth knowing:
- Callers rescue Radfish errors, not Faraday errors.
HttpClientconverts Faraday's connection, timeout and SSL failures intoRadfish::ConnectionErrorandRadfish::TimeoutError. Code above the seam that rescuesFaraday::Errorcatches nothing. - Adapters that wrap another gem are outside the seam. The Dell and
Supermicro adapters delegate to the
idracandsupermicrogems, which have their own HTTP stacks, so the behaviour described here does not apply to their requests.
Errors
All library errors descend from Radfish::Error, so one rescue catches
everything the library raises:
Radfish::Error
Retries
Failed requests are retried with an exponential backoff on 408, 429, 500, 502, 503 and 504, and on connection and timeout failures. Only idempotent methods are retried - GET, HEAD, PUT and DELETE. A repeated POST is not safe on Redfish: it can mean a second session, a second reset, or a second job. A caller that knows its POST is safe to repeat can widen the set for one client:
Radfish::HttpClient.new(
host: '192.168.1.100',
retry_count: 3, # attempts after the first
retry_delay: 1, # initial delay, doubled each retry
retry_methods: Radfish::HttpClient::IDEMPOTENT_METHODS + [:post]
)
For a whole operation rather than a single request, BaseClient#with_retries
wraps a block.
Redirects
Some BMCs (AMI MegaRAC, for one) redirect /redfish/v1 to /redfish/v1/.
HttpClient follows redirects on GET and HEAD, up to max_redirects hops
(3 by default; pass max_redirects: 0 on a call to get the 3xx response
itself). A redirect is only followed back to the same endpoint - a relative
path, or an absolute URL whose scheme, host and port match the BMC already
being addressed - because every request carries credentials and Faraday would
otherwise hand them to whatever host the Location header named. POST and
PATCH redirects are returned to the caller rather than followed, since
301/302/303 do not preserve the method.
Features
Automatic Vendor Detection
- Automatically identifies Dell, Supermicro, HPE, Lenovo, and ASRockRack servers
- Falls back to generic Redfish if vendor cannot be determined
- Can be overridden with explicit vendor specification
Unified Interface
Regardless of vendor, all adapters provide:
- Power Management: on/off/restart/cycle
- System Inventory: CPUs, memory, NICs, storage
- Virtual Media: Mount/unmount ISOs
- Boot Configuration: Boot order, one-time boot
- Monitoring: Temperatures, fans, power consumption
- Event Logs: System event log management
- Jobs/Tasks: Long-running operation monitoring
Vendor-Specific Features
Adapters can expose vendor-specific functionality while maintaining the common interface.
Compatibility
activesupport below 8.1 and json 3 cannot be used together: activesupport's
JSON encoder calls JSON.generate(..., quirks_mode: true), and json 3 removed
that keyword, so any hash.to_json raises ArgumentError: unknown keyword: quirks_mode. This is not specific to this gem — it bites anything that loads
active_support/core_ext — but radfish depends on activesupport, so pick one
of:
- activesupport >= 8.1 with json 3, or
- activesupport 7.x with json 2.
CI covers both ends.
Installation
Add to your Gemfile:
gem 'radfish'
# Add vendor-specific adapters as needed
gem 'radfish-idrac' # For Dell servers
gem 'radfish-supermicro' # For Supermicro servers
Or install directly:
gem install radfish
gem install radfish-idrac # For Dell servers
gem install radfish-supermicro # For Supermicro servers
The adapters will be automatically detected and loaded when available.
CLI Usage
Radfish includes a powerful command-line interface for server management:
Quick Start
# Check system status
radfish system --host 192.168.1.100 -u admin -p password
# Power operations
radfish power status --host 192.168.1.100 -u admin -p password
radfish power on --host 192.168.1.100 -u admin -p password
radfish power restart --host 192.168.1.100 -u admin -p password
# Virtual media operations
radfish media status --host 192.168.1.100 -u admin -p password
radfish media mount https://example.com/ubuntu.iso --host 192.168.1.100 -u admin -p password
radfish media unmount --host 192.168.1.100 -u admin -p password
# Boot configuration
radfish boot status --host 192.168.1.100 -u admin -p password
radfish boot cd --once --host 192.168.1.100 -u admin -p password
radfish boot pxe --uefi --host 192.168.1.100 -u admin -p password
Environment Variables
Configure common settings via environment variables to avoid repetition:
export RADFISH_HOST=192.168.1.100
export RADFISH_USERNAME=admin
export RADFISH_PASSWORD=password
export RADFISH_VENDOR=supermicro # Optional: auto-detects if not set
export RADFISH_PORT=443 # Optional: defaults to 443
# Now commands are simpler
radfish system
radfish power on
radfish media mount https://example.com/ubuntu.iso
Available Commands
System Information
radfish system [OPTIONS] # Display system information
radfish cpus [OPTIONS] # List CPUs
radfish memory [OPTIONS] # List memory modules
radfish nics [OPTIONS] # List network interfaces
radfish storage controllers # List storage controllers
radfish storage drives # List drives across controllers
radfish storage volumes # List volumes across controllers
radfish psus [OPTIONS] # List power supplies
Power Management
radfish power status [OPTIONS] # Show current power state
radfish power on [OPTIONS] # Power on the system
radfish power off [OPTIONS] # Power off the system
radfish power restart [OPTIONS] # Restart the system
radfish power cycle [OPTIONS] # Power cycle the system
Virtual Media
radfish media status [OPTIONS] # Show virtual media status
radfish media mount URL [OPTIONS] # Mount ISO from URL
radfish media unmount [OPTIONS] # Unmount all virtual media
Boot Configuration
radfish boot status [OPTIONS] # Show boot configuration
radfish boot cd [OPTIONS] # Boot from virtual CD
radfish boot pxe [OPTIONS] # Boot from network (PXE)
radfish boot disk [OPTIONS] # Boot from hard disk
radfish boot bios [OPTIONS] # Boot to BIOS setup
# Boot options:
--once # Set boot override for next boot only
--continuous # Set boot override until manually cleared
--uefi # Use UEFI boot mode
--legacy # Use Legacy/BIOS boot mode
Monitoring
radfish fans [OPTIONS] # Show fan speeds
radfish temps [OPTIONS] # Show temperatures
radfish power-consumption [OPTIONS] # Show power consumption
radfish sel [OPTIONS] # Show system event log
radfish clear-sel [OPTIONS] # Clear system event log
Global Options
All commands support these options:
--host, -h HOST # BMC hostname or IP address
--username, -u USER # BMC username
--password, -p PASS # BMC password
--vendor, -v VENDOR # Force specific vendor (dell, supermicro, etc.)
--port PORT # BMC port (default: 443)
--config, -c FILE # Read options from a YAML config file
--json # Output in JSON format
--verbose # Application-level progress messages
--debug [N] # HTTP-level debug output (default 2, see below)
--insecure # Skip SSL certificate verification (default: true)
--verbose and --debug set the same verbosity level, and --debug wins:
| Level | Flag | Output |
|---|---|---|
| 0 | (none) | Results only |
| 1 | --verbose |
Progress messages from the library |
| 2 | --debug |
Adds the HTTP request and response log |
| 3 | --debug 3 |
Adds request and response bodies, and call sites |
The Authorization header and password fields are filtered out of the log, but
level 3 prints request and response bodies, which can carry other sensitive
data - read it before pasting it into an issue.
Output Formats
Default (Human-Readable)
$ radfish system
System Information:
Manufacturer: Supermicro
Model: X11SCL-F
Serial: 0123456789
Power State: On
Health: OK
JSON Format
$ radfish system --json
{
"manufacturer": "Supermicro",
"model": "X11SCL-F",
"serial": "0123456789",
"power_state": "On",
"health": "OK"
}
Common Workflows
Mount ISO and Boot from It
# Mount the ISO
radfish media mount https://releases.ubuntu.com/24.04/ubuntu-24.04-live-server-amd64.iso
# Configure one-time boot from CD with UEFI
radfish boot cd --once --uefi
# Restart the system
radfish power restart
Power Cycle with Monitoring
# Check current status
radfish power status
radfish temps
# Perform power cycle
radfish power cycle
# Monitor until back online
watch radfish power status
Automated Script Example
#!/bin/bash
# Provision multiple servers
SERVERS="192.168.1.100 192.168.1.101 192.168.1.102"
ISO_URL="https://example.com/os-installer.iso"
for server in $SERVERS; do
echo "Provisioning $server..."
# Mount ISO
radfish media mount $ISO_URL --host $server -u admin -p password
# Set one-time boot from CD
radfish boot cd --once --host $server -u admin -p password
# Restart
radfish power restart --host $server -u admin -p password
done
Library Usage
Basic Usage with Auto-Detection
require 'radfish'
# Auto-detect vendor and connect
Radfish.connect(
host: '192.168.1.100',
username: 'admin',
password: 'password'
) do |client|
puts "Connected to #{client.vendor_name} server"
puts "Power state: #{client.power_status}"
# Common operations work regardless of vendor
client.power_on
client.insert_virtual_media("http://example.com/os.iso")
client.boot_to_cd
end
Explicit Vendor Specification
# Skip auto-detection if you know the vendor
client = Radfish::Client.new(
host: '192.168.1.100',
username: 'admin',
password: 'password',
vendor: 'dell' # or 'supermicro', 'hpe', etc.
)
client.login
# ... operations ...
client.logout
Vendor Detection Only
# Just detect the vendor without creating a client
vendor = Radfish.detect_vendor(
host: '192.168.1.100',
username: 'admin',
password: 'password'
)
puts "Detected vendor: #{vendor}"
# => "dell", "supermicro", "hpe", etc.
Checking Supported Features
client = Radfish::Client.new(
host: '192.168.1.100',
username: 'admin',
password: 'password'
)
# Check what this adapter supports
puts client.supported_features
# => [:power, :system, :storage, :virtual_media, :boot, :jobs, :utility]
# Get adapter info
puts client.info
# => {
# vendor: "supermicro",
# adapter: "Radfish::SupermicroAdapter",
# features: [:power, :system, ...],
# host: "192.168.1.100",
# base_url: "https://192.168.1.100:443"
# }
Common Operations
Power Management
client.power_status # => "On" or "Off"
client.power_on
client.power_off
client.power_restart
client.power_cycle
System Information
# Basic system info
info = client.system_info
# => { "manufacturer" => "Dell", "model" => "PowerEdge R640", ... }
# Hardware inventory
client.cpus # CPU information
client.memory # Memory DIMMs
client.nics # Network interfaces
client.controllers.each { |c| c.drives } # Physical drives (per controller)
client.controllers.each { |c| c.volumes } # RAID volumes (per controller)
client.psus # Power supplies
Virtual Media
# Check current media
media = client.virtual_media_status
# Mount an ISO
client.insert_virtual_media("http://example.com/os.iso")
# Unmount all media
client.unmount_all_media
# Mount and configure boot
client.mount_iso_and_boot("http://example.com/os.iso")
Boot Configuration
# Get boot options
= client.
# Set one-time boot
client.set_boot_override("Pxe", persistence: 'Once')
# Quick boot methods
client.boot_to_pxe
client.boot_to_disk
client.boot_to_cd
client.boot_to_bios_setup
Monitoring
# Thermal monitoring
fans = client.fans
temps = client.temperatures
# Power monitoring
power = client.power_consumption
# Event logs
events = client.sel_summary(limit: 10)
client.clear_sel_log
Multi-Vendor Environments
Radfish shines in environments with mixed hardware vendors:
servers = [
{ host: '192.168.1.100', vendor: 'dell' },
{ host: '192.168.1.101', vendor: 'supermicro' },
{ host: '192.168.1.102', vendor: nil } # auto-detect
]
servers.each do |server_config|
Radfish.connect(
host: server_config[:host],
username: 'admin',
password: 'password',
vendor: server_config[:vendor]
) do |client|
# Same code works for all vendors
puts "#{client.vendor_name}: #{client.power_status}"
if client.power_status == "Off"
client.power_on
end
end
end
Configuration Options
Radfish::Client.new(
host: '192.168.1.100',
username: 'admin',
password: 'password',
# Optional parameters
vendor: 'dell', # Skip auto-detection
port: 443, # BMC port
use_ssl: true, # Use HTTPS
verify_ssl: false, # Verify certificates
direct_mode: false, # Use Basic Auth instead of sessions
retry_count: 3, # Retries after the first attempt
retry_delay: 1, # Initial delay between retries, doubled each time
retry_methods: nil, # Defaults to idempotent methods only
max_redirects: 3, # Same-endpoint redirects to follow (0 disables)
verbosity: 0 # Debug output level (0-3)
)
Debugging
Enable verbose output:
client.verbosity = 1 # Progress messages from the library
client.verbosity = 2 # Adds the HTTP request and response log
client.verbosity = 3 # Adds request and response bodies, and call sites
These are the same levels the CLI sets with --verbose and --debug N. The
Authorization header and password fields are filtered out of the log.
Supported Vendors
Currently supported:
- Dell (via radfish-idrac)
- Supermicro (via radfish-supermicro)
Planned support:
- HPE (iLO)
- Lenovo (XCC)
- ASRockRack
- Generic Redfish (fallback)
Creating Custom Adapters
To add support for a new vendor, create an adapter gem:
# radfish-myvendor/lib/radfish/myvendor_adapter.rb
module Radfish
class MyvendorAdapter < Core::BaseClient
include Core::Power
include Core::System
# ... include other modules
def vendor
'myvendor'
end
def power_status
# Implement vendor-specific logic
end
# ... implement required methods
end
# Register the adapter
Radfish.register_adapter('myvendor', MyvendorAdapter)
end
Benefits of the Unified Approach
- Single API: Learn once, use everywhere
- Vendor Flexibility: Switch hardware vendors without changing code
- Automatic Detection: No need to track which vendor each server uses
- Gradual Migration: Mix vendors during hardware transitions
- Simplified Testing: Mock one interface instead of many
- Future-Proof: New vendors can be added without changing existing code
Migration from Direct Vendor Gems
If you're currently using the idrac or supermicro gems directly:
# Old way (vendor-specific)
require 'idrac'
client = IDRAC::Client.new(host: '...', ...)
# New way (unified)
require 'radfish'
require 'radfish/idrac_adapter' # or let it auto-load
client = Radfish::Client.new(host: '...', vendor: 'dell')
# Or with auto-detection
client = Radfish::Client.new(host: '...')
The same method names work, so migration is straightforward.
License