BOSH VCloud Cloud Provider Interface

Introduction

It's a BOSH CPI implementation for a vCloud Director backed infrastructure cloud. In order to target a vCloud Director instance, MicroBosh must be set to use the vCloud plugin configuration as shown below:

---
plugin: vcloud
vcds
  - url:   
    user:      
    password: 
    entities:
      organization: 
      virtual_datacenter: 
      vapp_catalog: 
      media_catalog:
      media_storage_profile:
      vm_metadata_key:
      description:
      control: #optional parameters
        wait_max: #optional parameters     

Note that vCloud Director version 5.1 or newer is required.

Parameters

This section explains which parameters are supported in vCloud BOSH CPI.

  • url (required) The endpoint of the target vCloud Director
  • user (required) The user name of the target vCloud Director
  • password (required) The password of the target vCloud Director
  • organization (required) The organization name
  • virtual_datacenter (required) The virtual data center name
  • vapp_catalog (required) The name of the calalog for vapp template
  • media_catalog (required) The name of the calalog for media files
  • media_storage_profile (required) The storage profile to use. You can put * here to match all the storage profiles.
  • vm_metadata_key (required) The key name of VM metadata
  • description (required) Text associated with the VMs
  • Control (optional) All the following control parameters are optional
  • wait_max (optional) Maximum wait seconds for a single CPI task
  • wait_delay (optional) Delay in seconds for pooling next CPI task status
  • cookie_timeout (optional) The cookie timeout in seconds
  • retry_max (optional) Maximum retry times
  • retry_delay (optional) The delay of first retry, the next is *2

The network name should be specified under cloud_properties in the networks section of a BOSH deployment manifest. It should be the 'Org VDC Network' you plan to use for deployment.

Example

This is a sample of how vCloud Director specific properties are used in a BOSH deployment manifest:

---
networks:
- name: default 
  subnets:
    - reserved:
    - 192.168.21.129 - 192.168.21.150
    static:
    - 192.168.21.151 - 192.168.21.189
    range: 192.168.21.128/25
    gateway: 192.168.21.253
    dns:
    - 192.168.71.1
    cloud_properties:
      name: "tempest_vdc_network"

...

properties:
  vcd:
    url: https://192.168.10.1
    user: dev
    password: pwd
    entities:
      organization: dev
      virtual_datacenter: vdc
      vapp_catalog: cloudfoundry
      media_catalog: cloudfoundry 
      media_storage_profile: *
      vm_metadata_key: cf-agent-env
      description: Bosh on vCloudDirector